Evaporation Rate from an Open Tank or Pool

Evaporation rate from an open liquid surface from a mass transfer coefficient, the surface area and the vapour pressure difference (water from IF97 or any liquid).

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Hot well 50 °CAcetone tank

From a correlation for the air speed over the surface; your figure.

Results

Dilute mass transfer (no correction for high vapour pressure); the coefficient sets the accuracy.

Vapour pressure at the surface30.800kPa
Partial pressure in the air0kPa
Evaporation flux0.002165kg/(m²·s)
Evaporation rate38.967kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hot well 50 °C. The inputs, in the units selected above:

InputValue
LiquidWater (vapour pressure from IAPWS-IF97)
Liquid surface temperature50.000 °C
Mass transfer coefficient0.005000 m/s
Surface area20.000 m²
Air relative humidity (water)60.000 %
Air temperature (water)30.000 °C
Vapour pressure at the surface (other liquid)10.000 kPa
Partial pressure in the air (other liquid)0 kPa
Molar mass (other liquid)58.080 kg/kmol

Applying the formula below gives:

ResultValue
Vapour pressure at the surface12.351 kPa
Partial pressure in the air2.5480 kPa
Evaporation flux3.2302e-04 kg/(m²·s)
Evaporation rate23.258 kg/h

Open this example in the calculator and change any input.

Formula

\(N = k_c\frac{M}{R}\left(\frac{p_s}{T_s} - \frac{p_\infty}{T_a}\right), \quad \dot m = N A\)

Variables

Symbol Meaning SI unit
\(\text{liquid}\) Liquid -
\(T_s\) Liquid surface temperature K
\(k_c\) Mass transfer coefficient m/s
\(A\) Surface area m²
\(\varphi\) Air relative humidity (water) -
\(T_a\) Air temperature (water) K
\(p_v\) Vapour pressure at the surface (other liquid) Pa
\(p_\infty\) Partial pressure in the air (other liquid) Pa
\(M\) Molar mass (other liquid) kg/kmol
\(p_s\) Vapour pressure at the surface Pa
\(N\) Evaporation flux kg/(m²·s)
\(\dot m\) Evaporation rate kg/s

Method and standards

Film theory.

Where it is used

  • Hot wells, open tanks and drains.
  • Solvent storage losses.

Common mistakes

  • Air temperature for the surface.
  • Ignoring humidity of the air.

Assumptions and limits

  • Dilute vapour, steady state.
  • For water the air-side concentration is taken at the air temperature; for another liquid the air temperature is not an input and the surface temperature is used for both.
  • The mass transfer coefficient is your figure; the result is only as good as it is.

References

  • Film mass transfer N = k_c (C_s − C_∞)
  • C = pM/(RT); water vapour pressure from IAPWS-IF97

Questions and answers

20 m² of water at 50 °C in 30 °C, 60 % air, k_c 5 mm/s?

Roughly 23 kg/h of water.

Where does k_c come from?

Correlations with air speed over the surface; it is the main uncertainty.

Solvents?

Use their vapour pressure and molar mass; the result also feeds dilution ventilation.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.