Worked example
Example: Clean solvent. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Solute in the gas entering | 2.0000 % |
| Solute in the gas leaving | 0.10000 % |
| Solute in the liquid entering | 0 % |
| Equilibrium slope y = mx | 1.2000 - |
| Design multiple of the minimum | 1.5000 - |
| Gas molar flow | 100.00 kmol/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Minimum liquid-to-gas ratio | 1.1400 |
| Design ratio | 1.7100 |
| Liquid molar flow | 171.00 kmol/h |
| Solute in the leaving liquid | 1.1111 % |
Open this example in the calculator and change any input.
Formula
\(\left(\frac{L}{G}\right)_{min} = \frac{y_1 - y_2}{y_1/m - x_2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(y_1\) | Solute in the gas entering | - |
| \(y_2\) | Solute in the gas leaving | - |
| \(x_2\) | Solute in the liquid entering | - |
| \(m\) | Equilibrium slope y = mx | - |
| \(f\) | Design multiple of the minimum | - |
| \(G\) | Gas molar flow | mol/s |
| \((L/G)_{min}\) | Minimum liquid-to-gas ratio | - |
| \(L/G\) | Design ratio | - |
| \(L\) | Liquid molar flow | mol/s |
| \(x_1\) | Solute in the leaving liquid | - |
Method and standards
Mass balance at the pinch.
Where it is used
- Scrubber and absorber design.
- Checking existing columns.
Common mistakes
- Mass ratios.
- Curved equilibrium.
Assumptions and limits
- Dilute, straight equilibrium line.
- Mole fractions and total flows stand in for the exact solute-free ratios (Y = y/(1 − y), X, carrier flows G_s, L_s); the error grows with y₁, and the page warns above 10 % solute.
References
- Operating line through (x₂, y₂) touching equilibrium at the gas inlet: (L/G)_min = (y₁ − y₂)/(y₁/m − x₂)
Questions and answers
2 % to 0.1 %, m 1.2, clean solvent?
(L/G)_min 1.140; at 1.5 × that is 1.71.
Why 1.2–2 × minimum?
At the minimum the column would need infinite height.
Solvent cost?
Higher L/G means fewer stages but more pumping and regeneration.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.