FireCADCalc

Steam Blowing: Disturbance (Cleaning Force) Factor

Disturbance factor of a steam blow, the ratio of ṁ²v during the blow to that at maximum continuous rating at the same point, with IF97 specific volumes.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)BoilerSteam turbine

Inputs

Examples: Low pressure blowPuffing blowSaturated blow at 10 bar(a)

Results

A factor above 1 means the blow cleans harder than full-load operation will disturb; the target value is set by the turbine supplier.

Specific volume while blowing0.18658m³/kg
Specific volume at MCR0.050026m³/kg
Disturbance factor1.3427

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Low pressure blow. The inputs, in the units selected above:

InputValue
Blowing steam flow60.000 t/h
Blowing pressure at the point (absolute)15.000 bar
Blowing temperature (superheated)350.00 °C
Blowing steamSuperheated, at the temperature above
MCR steam flow100.00 t/h
MCR pressure at the point (absolute)66.000 bar
MCR temperature485.00 °C

Applying the formula below gives:

ResultValue
Specific volume while blowing0.18658 m³/kg
Specific volume at MCR0.050026 m³/kg
Disturbance factor1.3427

Open this example in the calculator and change any input.

Formula

\(K = \frac{\dot m_b^2 v_b}{\dot m_{MCR}^2 v_{MCR}}\)

Variables

Symbol Meaning SI unit
\(\dot m_b\) Blowing steam flow kg/s
\(p_b\) Blowing pressure at the point (absolute) Pa
\(T_b\) Blowing temperature (superheated) K
\(\text{state}_b\) Blowing steam: superheated or dry saturated -
\(\dot m_{MCR}\) MCR steam flow kg/s
\(p_{MCR}\) MCR pressure at the point (absolute) Pa
\(T_{MCR}\) MCR temperature K
\(v_b\) Specific volume while blowing m³/kg
\(v_{MCR}\) Specific volume at MCR m³/kg
\(K\) Disturbance factor -

Method and standards

Ratio of the momentum flux (ṁ²v, proportional to the dynamic pressure in a given bore) during the blow to that at MCR at the same point, with IAPWS-IF97 specific volumes.

Where it is used

  • Commissioning steam blows.

Common mistakes

  • Comparing at different points in the line.

Assumptions and limits

  • Same location and bore.
  • Blowing steam superheated, or dry saturated when chosen; wet steam is not covered.

References

  • Disturbance factor K = (ṁ²v)_blow/(ṁ²v)_MCR (momentum flux ratio); specific volumes from IAPWS-IF97

Questions and answers

Why ṁ²v?

Dynamic pressure ρv²/2 scales with ṁ²v for a given bore: it is the force that lifts debris.

Why low pressure blows work?

Low-pressure steam has a large specific volume, so a smaller flow reaches the same factor.

Target?

Above 1, by a margin the turbine supplier sets; follow the supplier's requirement.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.