Start-Up Steam to Vent or Bypass at Minimum Firing

Steam made at minimum stable firing during start-up (IF97) that must go to the start-up vent or bypass, and the heat it carries.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 12 MW minimum firingOil start-upVent at 2 bar(a), drum at 40 bar(a), feed 140 °C

The feedwater enthalpy is taken at the drum or feed pressure, which can be well above the vent pressure during start-up.

Results

Size the start-up vent and silencer for this flow; superheaters need it to keep cool before the turbine takes steam.

Steam to vent or bypass11.251t/h
Heat in the vented steam8.4000MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 12 MW minimum firing. The inputs, in the units selected above:

InputValue
Fuel heat input at minimum stable firing12.000 MW
Boiler efficiency at that firing70.000 %
Steam pressure at the vent (absolute)20.000 bar
Steam temperature300.00 °C
Feedwater temperature80.000 °C
Drum (feedwater) pressure (absolute)20.000 bar

Applying the formula below gives:

ResultValue
Steam to vent or bypass11.251 t/h
Heat in the vented steam8.4000 MW

Open this example in the calculator and change any input.

Formula

\(\dot m_s = \frac{\eta\,\dot Q_{min}}{h_s - h_{fw}}\)

Variables

Symbol Meaning SI unit
\(\dot Q_{min}\) Fuel heat input at minimum stable firing W
\(\eta\) Boiler efficiency at that firing -
\(p\) Steam pressure at the vent (absolute) Pa
\(T_s\) Steam temperature K
\(T_{fw}\) Feedwater temperature K
\(p_{fw}\) Drum (feedwater) pressure (absolute) Pa
\(h_s\), \(h_{fw}\) steam enthalpy at the vent (p, T_s) and feedwater enthalpy at (p_fw, T_fw), IF97 J/kg
\(\dot m_s\) Steam to vent or bypass kg/s
\(\dot Q_l\) Heat in the vented steam W

Method and standards

Energy balance: the heat absorbed at minimum firing (input times efficiency) all goes into raising steam from the feedwater to the vented state, with IAPWS-IF97 enthalpies (steam at the vent conditions, feedwater at the drum pressure).

Where it is used

  • Start-up vent and silencer sizing.
  • Start-up cost estimates.

Common mistakes

  • Full-load efficiency at minimum firing.

Assumptions and limits

  • Steady minimum firing.
  • Feedwater must be liquid at the drum pressure.
  • All the absorbed heat is taken to make vented steam. During a real start-up part of it heats the water and metal, so the vent flow found is an upper bound, suitable for sizing the vent and silencer.

References

  • Energy balance with IAPWS-IF97 enthalpies

Questions and answers

Why vent steam at start-up?

Superheater tubes need steam flow to stay cool before the turbine or process can take it.

Cost?

The vented heat is lost; shorter start-ups and bypass to a condenser recover some.

Minimum stable firing?

Set by burners or grate and by circulation: take it from the maker.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.