FireCADCalc

Soot Blowing Steam Consumption and Cost

Steam used by soot blowers per day from the number of blowers, flow, blowing time and cycles, with the heat and fuel it costs.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 12 blowers, 1.5 kg/s for 90 s, 3 cycles a day, 45 bar(a) / 400 °C6 rotary blowers, 0.8 kg/s for 60 s, 2 cycles, 17.5 bar(a) saturated24 long retractables, 2.5 kg/s for 180 s, 1 cycle, 110 bar(a) / 520 °CBlowers at 20 bar(a) / 480 °C through a PRV from a 110 bar(a) boiler, feed 230 °C

From the soot blower maker's data sheet.
The feedwater enthalpy is taken at the boiler pressure. If the blowers take steam through a reducing valve, enter the boiler pressure here; the valve keeps the steam enthalpy unchanged.

Results

Steam used per day0.57600t
Fuel to raise it, per day0.097192t
Fuel cost per day (your currency)583.15
Heat in the steam per day1.3558GJ

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 12 blowers, 1.5 kg/s for 90 s, 3 cycles a day, 45 bar(a) / 400 °C. The inputs, in the units selected above:

InputValue
Number of soot blowers12.000 -
Steam flow of one blower while blowing5,400.0 kg/h
Blowing time of one blower per cycle90.000 s
Cycles per day3.0000 -
Steam pressure at the blowers (absolute)45.000 bar
Steam conditionSuperheated at the temperature below
Steam temperature (superheated only)400.00 °C
Feedwater temperature140.00 °C
Boiler (feedwater) pressure (absolute)45.000 bar
Boiler efficiency (on GCV)80.000 %
Gross calorific value of the fuel, as fired18,600 kJ/kg
Fuel price per tonne (your currency)6,000.0 -

Applying the formula below gives:

ResultValue
Steam used per day4.8600 t
Fuel to raise it, per day0.85366 t
Fuel cost per day (your currency)5,121.9
Heat in the steam per day12.702 GJ

Open this example in the calculator and change any input.

Formula

\(m_s = n\,\dot m_b\,t_b\,N_c \qquad Q_d = m_s\,(h_s - h_{fw}) \qquad m_f = \frac{Q_d}{\eta_1\,GCV} \qquad C_d = m_f\,c_f\)

Variables

Symbol Meaning SI unit
\(n\) number of soot blowers –
\(\dot m_b\) steam flow of one blower while blowing kg/s
\(t_b\) blowing time of one blower per cycle s
\(N_c\) cycles per day –
\(p\) steam pressure at the blowers, absolute Pa
\(\text{state}\) saturated or superheated steam –
\(T_s\) steam temperature (superheated) K
\(T_{fw}\) feedwater temperature K
\(p_{fw}\) boiler (feedwater) pressure, absolute Pa
\(\eta_1\) boiler efficiency on GCV –
\(GCV\) gross calorific value J/kg
\(c_f\) fuel price per tonne, your currency –
\(m_s\) steam used per day kg
\(m_f\) fuel to raise it, per day kg
\(C_d\) fuel cost per day, your currency –
\(Q_d\) heat in the steam per day J
\(h_s\) steam enthalpy J/kg
\(h_{fw}\) feedwater enthalpy J/kg

Method and standards

Daily steam from the blower data; heat to raise it from feedwater with FireCAD's IAPWS-IF97 enthalpies; fuel from the boiler efficiency on GCV. The cost uses the fuel price per tonne you enter (mass in tonnes).

Where it is used

  • Optimising soot blowing frequency in coal, biomass and bagasse boilers.
  • Comparing steam soot blowing with acoustic or air blowing.
  • Including soot blowing in the make-up water and steam balance.

Common mistakes

  • Using the maker's flow at a different blowing pressure.
  • Forgetting that soot blowing steam is lost: it needs make-up water and treatment too.
  • Blowing every surface on a fixed schedule whatever its fouling.

Assumptions and limits

  • Steam taken from the boiler's own output; the cost covers fuel only, not water, treatment or wear.
  • The steam enthalpy is taken at the blower pressure and temperature (a reducing valve keeps it unchanged); the feedwater enthalpy at the boiler pressure.

References

  • IAPWS R7-97(2012) IF97
  • first law heat balance

Questions and answers

How much steam does soot blowing use?

12 blowers at 1.5 kg/s each for 90 s, three cycles a day, use 4.86 t of steam a day. At 45 bar(a) and 400 °C from 140 °C feedwater, raising it takes 12.7 GJ, 854 kg of coal at 80 % efficiency; at 6000 per tonne of coal that is about 5120 a day.

Is soot blowing worth its steam?

Usually, when the gas temperature rise it prevents is large: every 20 K of exit gas temperature is about 1 % of fuel. Compare the daily steam cost with the fuel saving from the flue gas temperature saving calculator, and blow on need (gas temperature or pressure drop) rather than by the clock.

Where do I get the blower's steam flow?

From the soot blower maker's data sheet; it depends on the nozzle and the blowing pressure. Long retractable blowers use much more than wall blowers.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.