FireCADCalc

Riveted Joint Strength and Efficiency

Tearing, shearing and crushing strengths of a riveted lap or butt joint over one pitch, and the joint efficiency against the solid plate, by textbook strength of materials.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileBoilerTank and drumBoiler attendant and boiler operator examinations

Inputs

Examples: Double riveted lap: 12 mm plate, 21 mm holes, 70 mm pitchDouble riveted butt, double shear factor 1.875: 16 mm, 23 mm, 90 mmSingle riveted lap: 10 mm, 17.5 mm, 45 mm

1 for single riveted, 2 for double riveted, and so on.
2 in theory; some codes and textbooks use 1.875.

Results

The joint fails first by tearing of the plate.

Textbook strength-of-materials check over one pitch; it is not a design to any boiler code.

Tearing strength of the plate between holes (p − d) t σ_t85.760kN
Shearing strength of the rivets93.482kN
Crushing strength n d t σ_c88.320kN
Strength of the solid plate p t σ_t115.20kN
Strength of the joint (least of the three)85.760kN
Joint efficiency74.444%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Double riveted lap: 12 mm plate, 21 mm holes, 70 mm pitch. The inputs, in the units selected above:

InputValue
Plate thickness12.000 mm
Rivet hole diameter21.000 mm
Pitch of the rivets70.000 mm
Rivets per pitch length2.0000 -
Rivets inSingle shear (lap joint)
Double-shear factor2.0000 -
Allowable tensile stress of the plate80.000 MPa
Allowable shear stress of the rivets60.000 MPa
Allowable crushing stress120.00 MPa

Applying the formula below gives:

ResultValue
Tearing strength of the plate between holes (p − d) t σ_t47.040 kN
Shearing strength of the rivets41.563 kN
Crushing strength n d t σ_c60.480 kN
Strength of the solid plate p t σ_t67.200 kN
Strength of the joint (least of the three)41.563 kN
Joint efficiency61.850 %

Open this example in the calculator and change any input.

Formula

\(P_t = (p - d)\, t\, \sigma_t, \quad P_s = n\, k_s\, \frac{\pi d^2}{4}\, \tau \;\; (k_s = 1 \text{ single shear},\ k_s = k \text{ double shear}), \quad P_c = n\, d\, t\, \sigma_c\)

\(\eta = \frac{\min(P_t, P_s, P_c)}{p\, t\, \sigma_t}\)

Variables

Symbol Meaning SI unit
\(t\) Plate thickness m
\(d\) Rivet hole diameter m
\(p\) Pitch of the rivets m
\(n\) Rivets per pitch length -
\(\text{shear}\) Rivets in -
\(k\) Double-shear factor -
\(\sigma_t\) Allowable tensile stress of the plate Pa
\(\tau\) Allowable shear stress of the rivets Pa
\(\sigma_c\) Allowable crushing stress Pa
\(P_t\) Tearing strength of the plate between holes (p − d) t σ_t N
\(P_s\) Shearing strength of the rivets N
\(P_c\) Crushing strength n d t σ_c N
\(P\) Strength of the solid plate p t σ_t N
\(P_{min}\) Strength of the joint (least of the three) N
\(\eta\) Joint efficiency -

Method and standards

Strength of one pitch length of the joint in each failure mode, compared with the strength of the unpierced plate.

Worked example

A double riveted lap joint joins 12 mm plates with rivets in 21 mm holes at 70 mm pitch. Allowable stresses: tension 80 MPa, shear 60 MPa, crushing 120 MPa.

  • Tearing = (70 − 21) × 12 × 80 = 47.0 kN
  • Shearing = 2 × π/4 × 21² × 60 = 41.6 kN
  • Crushing = 2 × 21 × 12 × 120 = 60.5 kN
  • Solid plate = 70 × 12 × 80 = 67.2 kN; efficiency = 41.6 / 67.2 = 61.9 %

Where it is used

  • Boiler attendant and operator examinations.
  • Riveted tanks, old boiler shells and structural repairs.
  • Teaching joint design.

Common mistakes

  • Using rivet diameter instead of hole diameter.
  • Counting rivets in the whole joint instead of per pitch.
  • Forgetting the double-shear factor for butt joints.

Assumptions and limits

  • Static strength; no allowance for corrosion or fatigue.
  • Not a code design.
  • For a butt joint with cover plates, tearing and crushing use the main plate thickness; the cover plates (each usually thinner than the plate, two together thicker) are assumed not to govern.

References

  • Strength of riveted joints per pitch length (textbook strength of materials)

Questions and answers

What is the efficiency of a double riveted lap joint: 12 mm plate, 21 mm holes, 70 mm pitch?

Per pitch: tearing 47.0 kN, shearing 41.6 kN, crushing 60.5 kN, solid plate 67.2 kN. The weakest is shearing, so the efficiency is 61.9 %.

Why use 1.875 for double shear?

A rivet in double shear is in theory twice as strong; some codes and textbooks credit only 1.875 times. Choose the factor you were taught.

Is this a design to the boiler regulations?

No. It is the strength-of-materials method; code design uses the code's own rules and allowable stresses.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.