Worked example
Example: Double riveted lap: 12 mm plate, 21 mm holes, 70 mm pitch. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Plate thickness | 12.000 mm |
| Rivet hole diameter | 21.000 mm |
| Pitch of the rivets | 70.000 mm |
| Rivets per pitch length | 2.0000 - |
| Rivets in | Single shear (lap joint) |
| Double-shear factor | 2.0000 - |
| Allowable tensile stress of the plate | 80.000 MPa |
| Allowable shear stress of the rivets | 60.000 MPa |
| Allowable crushing stress | 120.00 MPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tearing strength of the plate between holes (p − d) t σ_t | 47.040 kN |
| Shearing strength of the rivets | 41.563 kN |
| Crushing strength n d t σ_c | 60.480 kN |
| Strength of the solid plate p t σ_t | 67.200 kN |
| Strength of the joint (least of the three) | 41.563 kN |
| Joint efficiency | 61.850 % |
Open this example in the calculator and change any input.
Formula
\(P_t = (p - d)\, t\, \sigma_t, \quad P_s = n\, k_s\, \frac{\pi d^2}{4}\, \tau \;\; (k_s = 1 \text{ single shear},\ k_s = k \text{ double shear}), \quad P_c = n\, d\, t\, \sigma_c\)
\(\eta = \frac{\min(P_t, P_s, P_c)}{p\, t\, \sigma_t}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(t\) | Plate thickness | m |
| \(d\) | Rivet hole diameter | m |
| \(p\) | Pitch of the rivets | m |
| \(n\) | Rivets per pitch length | - |
| \(\text{shear}\) | Rivets in | - |
| \(k\) | Double-shear factor | - |
| \(\sigma_t\) | Allowable tensile stress of the plate | Pa |
| \(\tau\) | Allowable shear stress of the rivets | Pa |
| \(\sigma_c\) | Allowable crushing stress | Pa |
| \(P_t\) | Tearing strength of the plate between holes (p − d) t σ_t | N |
| \(P_s\) | Shearing strength of the rivets | N |
| \(P_c\) | Crushing strength n d t σ_c | N |
| \(P\) | Strength of the solid plate p t σ_t | N |
| \(P_{min}\) | Strength of the joint (least of the three) | N |
| \(\eta\) | Joint efficiency | - |
Method and standards
Strength of one pitch length of the joint in each failure mode, compared with the strength of the unpierced plate.
Worked example
A double riveted lap joint joins 12 mm plates with rivets in 21 mm holes at 70 mm pitch. Allowable stresses: tension 80 MPa, shear 60 MPa, crushing 120 MPa.
- Tearing = (70 − 21) × 12 × 80 = 47.0 kN
- Shearing = 2 × π/4 × 21² × 60 = 41.6 kN
- Crushing = 2 × 21 × 12 × 120 = 60.5 kN
- Solid plate = 70 × 12 × 80 = 67.2 kN; efficiency = 41.6 / 67.2 = 61.9 %
Where it is used
- Boiler attendant and operator examinations.
- Riveted tanks, old boiler shells and structural repairs.
- Teaching joint design.
Common mistakes
- Using rivet diameter instead of hole diameter.
- Counting rivets in the whole joint instead of per pitch.
- Forgetting the double-shear factor for butt joints.
Assumptions and limits
- Static strength; no allowance for corrosion or fatigue.
- Not a code design.
- For a butt joint with cover plates, tearing and crushing use the main plate thickness; the cover plates (each usually thinner than the plate, two together thicker) are assumed not to govern.
References
- Strength of riveted joints per pitch length (textbook strength of materials)
Questions and answers
What is the efficiency of a double riveted lap joint: 12 mm plate, 21 mm holes, 70 mm pitch?
Per pitch: tearing 47.0 kN, shearing 41.6 kN, crushing 60.5 kN, solid plate 67.2 kN. The weakest is shearing, so the efficiency is 61.9 %.
Why use 1.875 for double shear?
A rivet in double shear is in theory twice as strong; some codes and textbooks credit only 1.875 times. Choose the factor you were taught.
Is this a design to the boiler regulations?
No. It is the strength-of-materials method; code design uses the code's own rules and allowable stresses.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.