Boiler Feed Pump Minimum Flow from Temperature Rise

Minimum flow through a feed pump so the water does not heat above an allowed rise, from shaft power and efficiency at low flow and IF97 specific heat.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Pump

Inputs

Examples: 180 kW at 25 %HP feed pump

Results

Take the larger of this thermal minimum and the maker's hydraulic minimum flow; set the recirculation valve to it.

Water specific heat4.2221kJ/(kg·K)
Minimum flow14.389t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 180 kW at 25 %. The inputs, in the units selected above:

InputValue
Shaft power at minimum flow180.00 kW
Pump efficiency at minimum flow25.000 %
Allowed temperature rise8.0000 K
Suction pressure (absolute)6.0000 bar
Suction temperature105.00 °C

Applying the formula below gives:

ResultValue
Water specific heat4.2221 kJ/(kg·K)
Minimum flow14.389 t/h

Open this example in the calculator and change any input.

Formula

\(\dot m_{min} = \frac{P (1 - \eta)}{c_p \Delta T_{max}}\)

Variables

Symbol Meaning SI unit
\(P\) Shaft power at minimum flow W
\(\eta\) Pump efficiency at minimum flow -
\(\Delta T_{max}\) Allowed temperature rise K
\(p\) Suction pressure (absolute) Pa
\(T\) Suction temperature K
\(c_p\) Water specific heat J/(kg·K)
\(\dot m_{min}\) Minimum flow kg/s

Method and standards

Energy balance.

Where it is used

  • Recirculation valve sizing.
  • Pump protection.

Common mistakes

  • Using design-point efficiency at minimum flow.

Assumptions and limits

  • All losses \((1 - \eta)P\) heat the water passing through the pump once. If the recirculated water is throttled back to the suction, the hydraulic work \(\eta P\) also turns to heat in that loop, so the loop heats faster; the minimum flow here is per pass through the pump.
  • A warning is given when the suction temperature plus the allowed rise reaches saturation at suction pressure.

References

  • Energy balance: losses (1 − η)P heat the water; c_p from IAPWS-IF97

Questions and answers

Why a minimum flow?

At low flow nearly all pump power becomes heat; water can flash and the pump can seize.

Thermal or hydraulic minimum?

Makers also set a hydraulic minimum against recirculation and vibration: use the larger.

Allowed rise?

Small enough that the water stays well below saturation at suction pressure.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.