Worked example
Example: 46 to 36 bar, 30 t/h drawn. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water in drum, risers and downcomers | 40.000 t |
| Steel in contact with the water | 150.00 t |
| Steel specific heat | 0.50000 kJ/(kg·K) |
| Pressure at the trip (absolute) | 46.000 bar |
| Pressure reached (absolute) | 36.000 bar |
| Steam still drawn | 30.000 t/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stored energy released | 3,943.3 MJ |
| Steam made from stored energy | 2.2599 t |
| Time to fall to p₂ | 4.5198 min |
Open this example in the calculator and change any input.
Formula
\(E = M_w[h_f(p_1) - h_f(p_2)] + M_m c_m [T_s(p_1) - T_s(p_2)], \quad t = \frac{E}{h_{fg}(p_2)\,\dot m_s}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M_w\) | Water in drum, risers and downcomers | kg |
| \(M_m\) | Steel in contact with the water | kg |
| \(c_m\) | Steel specific heat | J/(kg·K) |
| \(p_1\) | Pressure at the trip (absolute) | Pa |
| \(p_2\) | Pressure reached (absolute) | Pa |
| \(\dot m_s\) | Steam still drawn | kg/s |
| \(E\) | Stored energy released | J |
| \(M_s\) | Steam made from stored energy | kg |
| \(t\) | Time to fall to p₂ | s |
Method and standards
A lumped energy balance between two saturation states with IAPWS-IF97: the heat given up by the saturated water and the steel as the saturation temperature falls from \(T_s(p_1)\) to \(T_s(p_2)\) makes steam at the latent heat of the lower pressure \(p_2\). The time follows from a constant steam draw. Holding the water mass constant and using \(h_{fg}(p_2)\), the largest latent heat in the range, gives slightly less steam and so a slightly shorter, conservative time than a step-by-step balance in which the water inventory falls as it flashes.
Where it is used
- Ride-through studies.
- Operator training.
Common mistakes
- Ignoring steel mass.
Assumptions and limits
- Saturated, well-mixed water; constant steam draw; no firing and no feedwater during the decay.
- Water mass held constant; a warning appears when the steam made exceeds 20 % of the water, when drum level may trip the boiler first.
References
- Energy balance of saturated water and steel between two saturation states (IAPWS-IF97)
Questions and answers
Why does a boiler keep steaming after a trip?
Hot water flashes as pressure falls, and the steel gives up heat.
Use?
Judging how long a turbine or process can ride through a fuel interruption.
Bagasse feeding hiccups?
Short interruptions are absorbed by this stored energy; long ones are not.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.