FireCADCalc

Boiler Warm-Up Time with Hot Gas

Time for hot gas to heat a boiler's water and steel between two temperatures, from the water equivalent, gas flow and UA, by Ganapathy's warm-up balance.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 50 t steel, 30 t water, 20 t/h gas at 500 °CHRSG hot start

Results

The average warm-up rate, 125 K/h, is above the 55 K/h that drum makers often allow; throttle the gas flow or temperature to keep thermal stress down.

Above 100 °C the boiler must be under pressure to stay unboiled; heat into steaming and venting is not included, and the water specific heat rises above 4.19 kJ/(kg·K) (about 4.4 at 180 °C), so the time is somewhat short.

Water equivalent (heat per kelvin)351.69MJ/K
e^(UA/W_g c_pg)585.04
Warm-up time1.0408h
Average heating rate124.90°C/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 t steel, 30 t water, 20 t/h gas at 500 °C. The inputs, in the units selected above:

InputValue
Steel mass (tubes, drums, casing)50,000 kg
Steel specific heat0.50240 kJ/(kg·K)
Water mass30,000 kg
Gas flow20.000 t/h
Gas specific heat1.1300 kJ/(kg·K)
Gas inlet temperature500.00 °C
Initial water/steel temperature30.000 °C
Final water/steel temperature180.00 °C
Overall conductance of the heating surface40.000 kW/K

Applying the formula below gives:

ResultValue
Water equivalent (heat per kelvin)150.72 MJ/K
e^(UA/W_g c_pg)585.04
Warm-up time2.5681 h
Average heating rate58.409 °C/h

Open this example in the calculator and change any input.

Formula

\(z = \frac{MC\,K}{W_g c_{pg}(K - 1)}\ln\frac{T_{g1} - t_1}{T_{g1} - t_2}, \quad K = e^{UA/(W_g c_{pg})}, \quad MC = M_s c_s + M_w c_w\)

Variables

Symbol Meaning SI unit
\(M_s\) Steel mass (tubes, drums, casing) kg
\(c_s\) Steel specific heat J/(kg·K)
\(M_w\) Water mass kg
\(W_g\) Gas flow kg/s
\(c_{pg}\) Gas specific heat J/(kg·K)
\(T_{g1}\) Gas inlet temperature K
\(t_1\) Initial water/steel temperature K
\(t_2\) Final water/steel temperature K
\(UA\) Overall conductance of the heating surface W/K
\(MC\) Water equivalent, heat per kelvin (displayed in MJ, read as MJ/K) J/K
\(K\) e^(UA/W_g c_pg) -
\(z\) Warm-up time s
\(dt/dz\) Average heating rate K/s
\(c_w\) Water specific heat 4 186.8 J/(kg·K)

Method and standards

Ganapathy's integrated warm-up balance.

Where it is used

  • Start-up planning for HRSGs and package boilers.
  • Firing rate limits.

Common mistakes

  • Ignoring drum stress limits.
  • Using UA at full load when the gas flow is lower.

Assumptions and limits

  • Water and metal at one temperature; no losses.
  • Constant water specific heat 4.1868 kJ/(kg·K) and no steaming: the final temperature should be below saturation at the boiler pressure. Above 100 °C the time is somewhat short because the specific heat rises.
  • A warning appears when the average rate exceeds 55 K/h, a common drum maker's limit.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q4.44
  • Eqs. (77)–(80)

Questions and answers

What is the water equivalent?

Steel mass × steel specific heat plus water mass × water specific heat.

Why does K appear?

The gas leaves at t + (T_g1 − t)/K; K = e^(UA/W c) comes from the exchanger with a boiling (uniform) cold side.

Are losses included?

No; the estimate is short by the casing and drum losses.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.