Packed-Tower Air Stripping: Air-to-Water Ratio, NTU, HTU and Height

Minimum and design air-to-water ratio, stripping factor, transfer units and packed height of a countercurrent air stripping tower for a volatile compound.

Inputs

Examples: PCE alone in the same tower (H 0.364, KLa 0.0077)TCE 100 to 2 ug/L, H 0.25, 0.02 m3/s, 1.2 m tower, KLa 0.01

Accepted: 1E-5 to 10 m³/s
Accepted: 0.0001 to 100
Accepted: 0.001 to 1,000,000 µg/L
Accepted: 0.0001 to 1,000,000 µg/L
Accepted: 1.05 to 20
Accepted: 1E-5 to 1 1/s
Accepted: 0.1 to 10 m

Results

Design on the compound with the lowest Henry's constant and at the coldest water. K_La comes from the Onda correlation or pilot data, usually with a 0.7–0.75 safety factor; the tower diameter is set by the allowable gas pressure drop.

Minimum air-to-water ratio2.3548
Design air-to-water ratio8.2418
Air flow0.82418m³/s
Stripping factor3.0000
Tower cross-section7.2966m²
Height of a transfer unit1.7799m
Number of transfer units2.4142
Packed height4.2969m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: PCE alone in the same tower (H 0.364, KLa 0.0077). The inputs, in the units selected above:

InputValue
Water flow0.10000 m³/s
Dimensionless Henry's constant at the water temperature0.36400 -
Influent concentration35.000 µg/L
Treatment objective5.0000 µg/L
Multiple of the minimum air-to-water ratio (about 3.5)3.5000 -
Overall mass transfer coefficient (with safety factor)0.007700 1/s
Tower diameter3.0480 m

Applying the formula below gives:

ResultValue
Minimum air-to-water ratio2.3548
Design air-to-water ratio8.2418
Air flow0.82418 m³/s
Stripping factor3.0000
Tower cross-section7.2966 m²
Height of a transfer unit1.7799 m
Number of transfer units2.4142
Packed height4.2969 m

Open this example in the calculator and change any input.

Formula

\(\left(\frac{Q_a}{Q}\right)_{min} = \frac{C_0 - C_e}{HC_0}, \quad S = \frac{Q_a}{Q}H\)

\(NTU = \frac{S}{S - 1}\ln\frac{1 + \frac{C_0}{C_e}(S - 1)}{S}, \quad HTU = \frac{Q}{AK_La}, \quad L = HTU\cdot NTU\)

Variables

Symbol Meaning SI unit
\(Q\) Water flow m³/s
\(H\) Dimensionless Henry's constant at the water temperature -
\(C_0\) Influent concentration kg/m³
\(C_e\) Treatment objective kg/m³
\(f\) Multiple of the minimum air-to-water ratio (about 3.5) -
\(K_La\) Overall mass transfer coefficient (with safety factor) 1/s
\(D_t\) Tower diameter m
\((Q_a/Q)_{min}\) Minimum air-to-water ratio -
\(Q_a/Q\) Design air-to-water ratio -
\(Q_a\) Air flow m³/s
\(S\) Stripping factor -
\(A\) Tower cross-section m²
\(HTU\) Height of a transfer unit m
\(NTU\) Number of transfer units -
\(L\) Packed height m

Method and standards

Countercurrent packed-tower design with constant Henry's law equilibrium.

Where it is used

  • VOC removal from groundwater.
  • Radon and CO₂ stripping.

Common mistakes

  • Using the Henry's constant at 20 °C for cold groundwater.
  • Applying the full Onda K_La without a safety factor.

Assumptions and limits

  • Dilute solutions, clean air inlet, plug flow of both phases.

Questions and answers

Why 3.5 times the minimum?

Designers report that about 3.5 times the minimum air-to-water ratio gives close to the least tower volume and power for typical VOCs.

What if several compounds are present?

Size the air ratio and height on the hardest (lowest Henry's constant, highest removal); the others are then over-removed.

What do the defaults represent?

An illustrative case: PCE alone in the same tower (H 0.364, KLa 0.0077). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 14-5, eqs. 14-26, 14-28 and 14-48 to 14-50, Examples 14-3 and 14-7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.