Worked example
Example: PCE alone in the same tower (H 0.364, KLa 0.0077). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water flow | 0.10000 m³/s |
| Dimensionless Henry's constant at the water temperature | 0.36400 - |
| Influent concentration | 35.000 µg/L |
| Treatment objective | 5.0000 µg/L |
| Multiple of the minimum air-to-water ratio (about 3.5) | 3.5000 - |
| Overall mass transfer coefficient (with safety factor) | 0.007700 1/s |
| Tower diameter | 3.0480 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Minimum air-to-water ratio | 2.3548 |
| Design air-to-water ratio | 8.2418 |
| Air flow | 0.82418 m³/s |
| Stripping factor | 3.0000 |
| Tower cross-section | 7.2966 m² |
| Height of a transfer unit | 1.7799 m |
| Number of transfer units | 2.4142 |
| Packed height | 4.2969 m |
Open this example in the calculator and change any input.
Formula
\(\left(\frac{Q_a}{Q}\right)_{min} = \frac{C_0 - C_e}{HC_0}, \quad S = \frac{Q_a}{Q}H\)
\(NTU = \frac{S}{S - 1}\ln\frac{1 + \frac{C_0}{C_e}(S - 1)}{S}, \quad HTU = \frac{Q}{AK_La}, \quad L = HTU\cdot NTU\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Water flow | m³/s |
| \(H\) | Dimensionless Henry's constant at the water temperature | - |
| \(C_0\) | Influent concentration | kg/m³ |
| \(C_e\) | Treatment objective | kg/m³ |
| \(f\) | Multiple of the minimum air-to-water ratio (about 3.5) | - |
| \(K_La\) | Overall mass transfer coefficient (with safety factor) | 1/s |
| \(D_t\) | Tower diameter | m |
| \((Q_a/Q)_{min}\) | Minimum air-to-water ratio | - |
| \(Q_a/Q\) | Design air-to-water ratio | - |
| \(Q_a\) | Air flow | m³/s |
| \(S\) | Stripping factor | - |
| \(A\) | Tower cross-section | m² |
| \(HTU\) | Height of a transfer unit | m |
| \(NTU\) | Number of transfer units | - |
| \(L\) | Packed height | m |
Method and standards
Countercurrent packed-tower design with constant Henry's law equilibrium.
Where it is used
- VOC removal from groundwater.
- Radon and CO₂ stripping.
Common mistakes
- Using the Henry's constant at 20 °C for cold groundwater.
- Applying the full Onda K_La without a safety factor.
Assumptions and limits
- Dilute solutions, clean air inlet, plug flow of both phases.
Questions and answers
Why 3.5 times the minimum?
Designers report that about 3.5 times the minimum air-to-water ratio gives close to the least tower volume and power for typical VOCs.
What if several compounds are present?
Size the air ratio and height on the hardest (lowest Henry's constant, highest removal); the others are then over-removed.
What do the defaults represent?
An illustrative case: PCE alone in the same tower (H 0.364, KLa 0.0077). Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 14-5, eqs. 14-26, 14-28 and 14-48 to 14-50, Examples 14-3 and 14-7