FireCADCalc

Ion Exchange Binary Equilibrium: Maximum Loading and Bed Volumes

Maximum useful resin loading of a target ion against a competing ion from the separation factor and total capacity, and the bed volumes treated to exhaustion.

Inputs

Examples: Low chloride 0.5 meq/LPerchlorate 0.0005 meq/L against 3 meq/L chloride, alpha 150

Accepted: 1E-6 to 10,000
Accepted: 0 to 10,000
Accepted: 0.01 to 1,000
Accepted: 0.1 to 5

Results

Enter the water concentrations in meq/L; the bed volumes are litres of water per litre of resin. Equilibrium (no mass-transfer zone) gives the upper limit of the run; other competing ions such as sulfate shorten it.

Reverse separation factor0.006667
Equivalent fraction of the target in water0.016664%
Equivalent fraction of the target on the resin at equilibrium2.4390%
Maximum loading of the target, meq/L of resin29.268
Bed volumes treated to exhaustion58,537

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Low chloride 0.5 meq/L. The inputs, in the units selected above:

InputValue
Target ion in the water (e.g. nitrate)1.8000 -
Competing (presaturant) ion, same unit (e.g. chloride)0.50000 -
Separation factor of the target over the competing ion3.2000 -
Total resin capacity, eq/L of resin1.4000 -

Applying the formula below gives:

ResultValue
Reverse separation factor0.31250
Equivalent fraction of the target in water78.261 %
Equivalent fraction of the target on the resin at equilibrium92.013 %
Maximum loading of the target, meq/L of resin1,288.2
Bed volumes treated to exhaustion715.65

Open this example in the calculator and change any input.

Formula

\(q_i = \frac{C_iq_T}{C_i + C_j\alpha_{j/i}}, \quad \alpha_{j/i} = \frac{1}{\alpha_{i/j}}, \quad BV = \frac{q_i}{C_i}\)

Variables

Symbol Meaning SI unit
\(C_i\) Target ion in the water (e.g. nitrate) -
\(C_j\) Competing (presaturant) ion, same unit (e.g. chloride) -
\(\alpha_{i/j}\) Separation factor of the target over the competing ion -
\(q_T\) Total resin capacity, eq/L of resin -
\(\alpha_{j/i}\) Reverse separation factor -
\(x_i\) Equivalent fraction of the target in water -
\(y_i\) Equivalent fraction of the target on the resin at equilibrium -
\(q_i\) Maximum loading of the target, meq/L of resin -
\(BV\) Bed volumes treated to exhaustion -

Method and standards

Binary exchange equilibrium with a constant separation factor.

Where it is used

  • Nitrate, perchlorate or arsenic ion exchange screening.
  • Run length estimates.

Common mistakes

  • Using mg/L instead of meq/L.
  • Inverting the separation factor.

Assumptions and limits

  • Two ions only; equilibrium loading.

Questions and answers

What is the separation factor?

The ratio of the resin's preference for one ion over another, α = (y_i x_j)/(x_i y_j); nitrate over chloride is about 3–4 on strong-base resin.

Why is high chloride a problem?

The competing ion takes resin sites; the higher its concentration the less target ion the resin holds.

What do the defaults represent?

An illustrative case: Low chloride 0.5 meq/L. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 16-4, eq. 16-22, Table 16-7 and Example 16-3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.