FireCADCalc

GAC Carbon Usage Rate, Throughput and Bed Life from Freundlich

Equilibrium loading, minimum carbon usage rate, specific throughput, carbon mass, water treated and bed life of a GAC contactor from Freundlich constants.

Inputs

Examples: Atrazine 0.01 mg/L, K 40, 1/n 0.30, 480 g/L, 1,000 L/min, 15 minChloroform 0.2 mg/L, K 2.6, 1/n 0.73, 450 g/L, 200 L/min, 20 min

Accepted: 1E-6 to 1,000 mg/L
Accepted: 0.0001 to 10,000
Accepted: 0.01 to 2
Accepted: 200 to 800 kg/m³
Accepted: 0.06 to 600,000 L/min
Accepted: 1 to 600 min

Results

q_e in mg/g. This is the best case: a single compound, a sharp mass transfer zone and no competition. Natural organic matter and the mass transfer zone often cut real bed life by half or more; confirm with RSSCT or pilot columns.

Equilibrium carbon loading10.048
Carbon usage rate (minimum)9.9527e-04g/L
Specific throughput1,004.8L/g
Bed volume15.000m³
Carbon in the bed7,200.0kg
Water treated to breakthrough (ideal)7,234,233m³
Bed life (ideal)5,023.8d
Bed volumes treated482,282

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Atrazine 0.01 mg/L, K 40, 1/n 0.30, 480 g/L, 1,000 L/min, 15 min. The inputs, in the units selected above:

InputValue
Influent concentration0.010000 mg/L
Freundlich capacity, (mg/g)(L/mg)^(1/n)40.000 -
Freundlich intensity 1/n0.30000 -
GAC bed density480.00 kg/m³
Flow1,000.0 L/min
Empty-bed contact time15.000 min

Applying the formula below gives:

ResultValue
Equilibrium carbon loading10.048
Carbon usage rate (minimum)9.9527e-04 g/L
Specific throughput1,004.8 L/g
Bed volume15.000 m³
Carbon in the bed7,200.0 kg
Water treated to breakthrough (ideal)7,234,233 m³
Bed life (ideal)5,023.8 d
Bed volumes treated482,282

Open this example in the calculator and change any input.

Formula

\(q_e = KC_0^{1/n}, \quad CUR = \frac{C_0}{q_e}\)

\(M_{GAC} = Q\cdot EBCT\cdot\rho_b, \quad V_t = \frac{M_{GAC}}{CUR}, \quad t_{bed} = \frac{V_t}{Q}\)

Variables

Symbol Meaning SI unit
\(C_0\) Influent concentration kg/m³
\(K\) Freundlich capacity, (mg/g)(L/mg)^(1/n) -
\(1/n\) Freundlich intensity 1/n -
\(\rho_b\) GAC bed density kg/m³
\(Q\) Flow m³/s
\(EBCT\) Empty-bed contact time s
\(q_e\) Equilibrium carbon loading -
\(CUR\) Carbon usage rate (minimum) kg/m³
\(1/CUR\) Specific throughput m³/kg
\(V_b\) Bed volume m³
\(M_{GAC}\) Carbon in the bed kg
\(V_t\) Water treated to breakthrough (ideal) m³
\(t_{bed}\) Bed life (ideal) s
\(BV\) Bed volumes treated -

Method and standards

Equilibrium (ideal) carbon usage from the Freundlich isotherm.

Where it is used

  • Screening GAC for groundwater VOCs.
  • Estimating carbon replacement frequency.

Common mistakes

  • Using isotherm constants with different units of C.
  • Treating the ideal bed life as the design bed life.

Assumptions and limits

  • Single solute, equilibrium loading at the influent concentration, no mass transfer zone.

Questions and answers

What EBCT is usual?

10–20 minutes for taste, odour and synthetic organics; longer for NOM or DBP precursor removal.

Why is the real CUR higher?

Competitive adsorption by NOM, preloading and the length of the mass transfer zone mean carbon is replaced before it reaches equilibrium.

What do the defaults represent?

An illustrative case: Atrazine 0.01 mg/L, K 40, 1/n 0.30, 480 g/L, 1,000 L/min, 15 min. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 15-6, eqs. 15-108 and 15-109 and Example 15-9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.