FireCADCalc

Brownian Motion versus Settling: Particle Size Where They Match

Particle size at which Brownian displacement equals Stokes settling in a given time, and both distances for a chosen particle size in water.

Inputs

Examples: Illustrative: clay-like particle 2000 kg/m3 at 15 C over 1 s, 0.5 um examinedOrganic floc 1050 kg/m3 over 1 hour, 2 um

Accepted: 1,001 to 10,000 kg/m³
Accepted: 950 to 1,050 kg/m³
Accepted: 0.2 to 2 mPa·s
Accepted: 0 to 80 °C
Accepted: 0.01 to 86,400 s
Accepted: 0.001 to 1,000 µm

Results

Brownian displacement x_B = (2Dt)^½ with D = kT/(3πμd_p), settling by Stokes' law. Particles much smaller than d_p,eq stay suspended by Brownian motion and do not settle in practical times.

Size at which Brownian and settling distances match1.2643µm
Settling distance of the chosen particle0.11979µm
Brownian displacement of the chosen particle1.2181µm
Brownian to settling ratio10.168
Particle diffusivity (Stokes–Einstein)7.4185e-13m²/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: clay-like particle 2000 kg/m3 at 15 C over 1 s, 0.5 um examined. The inputs, in the units selected above:

InputValue
Particle density2,000.0 kg/m³
Water density999.10 kg/m³
Water viscosity1.1380 mPa·s
Water temperature15.000 °C
Time1.0000 s
Particle diameter to examine0.50000 µm

Applying the formula below gives:

ResultValue
Size at which Brownian and settling distances match1.2643 µm
Settling distance of the chosen particle0.11979 µm
Brownian displacement of the chosen particle1.2181 µm
Brownian to settling ratio10.168
Particle diffusivity (Stokes–Einstein)7.4185e-13 m²/s

Open this example in the calculator and change any input.

Formula

\(d_{p,eq} = \left[\frac{216\,kT\mu}{\pi g^2(\rho_p - \rho_w)^2 t}\right]^{1/5}\)

\(x_s = \frac{g(\rho_p - \rho_w)d_p^2}{18\mu}t, \quad x_B = \sqrt{2Dt}, \quad D = \frac{kT}{3\pi\mu d_p}\)

Variables

Symbol Meaning SI unit
\(\rho_p\) Particle density kg/m³
\(\rho_w\) Water density kg/m³
\(\mu\) Water viscosity Pa·s
\(T\) Water temperature K
\(t\) Time s
\(d_p\) Particle diameter to examine m
\(d_{p,eq}\) Size at which Brownian and settling distances match m
\(x_s\) Settling distance of the chosen particle m
\(x_B\) Brownian displacement of the chosen particle m
\(x_B/x_s\) Brownian to settling ratio -
\(D\) Particle diffusivity (Stokes–Einstein) m²/s

Method and standards

Comparison of Stokes settling with Brownian displacement of spherical particles.

Where it is used

  • Explaining why coagulation is needed.
  • Judging which particles a settling basin can remove.

Common mistakes

  • Expecting sub-micron particles to settle.
  • Using the particle diameter in place of the radius in Stokes–Einstein (3πμd is for the diameter).

Assumptions and limits

  • Spheres, Stokes regime, dilute suspension.

References

  • Stokes' law and Stokes–Einstein Brownian displacement (2Dt)^½

Questions and answers

Why do colloids not settle?

Below about a micrometre, random Brownian movement in a second is larger than the settling distance, so the particles are kept in suspension; coagulation is needed to grow them.

Does time matter?

Yes: settling grows with t but Brownian displacement only with √t, so over longer times the crossover size falls slowly (as t^−1/5).

What do the defaults represent?

An illustrative clay-like particle (2000 kg/m³) in water at 15 °C over 1 s, with a 0.5 µm particle examined.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 10-2, Example 10-2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.