Worked example
Example: Small radon stripper 0.01 m3/s, A/W 30, 0.8 m2, 100 Pa/m, 4 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water flow | 0.010000 m³/s |
| Air-to-water ratio | 30.000 - |
| Tower cross-section | 0.80000 m² |
| Gas pressure drop per metre of packing | 100.00 Pa/m |
| Packing depth | 4.0000 m |
| Pumping lift (to the top of the tower) | 4.5000 m |
| Loss coefficient for demister, support and ducts, N·s²/m⁴ | 275.00 - |
| Air temperature | 15.000 °C |
| Ambient pressure | 101.33 kPa |
| Air density | 1.2250 kg/m³ |
| Water density | 999.10 kg/m³ |
| Blower efficiency | 50.000 % |
| Pump efficiency | 70.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air flow | 0.30000 m³/s |
| Air mass flow | 0.36750 kg/s |
| Demister, support and duct losses | 38.672 Pa |
| Blower discharge (tower inlet) pressure | 101.76 kPa |
| Blower brake power | 0.26275 kW |
| Pump brake power | 0.62986 kW |
| Total power | 0.89261 kW |
| Specific energy | 0.024795 kWh/m³ |
Open this example in the calculator and change any input.
Formula
\(P_{blower} = \frac{G_{me}RT}{M\,n_a\eta_b}\left[\left(\frac{P_{in}}{P_{out}}\right)^{n_a} - 1\right], \quad P_{in} = P_{amb} + \frac{\Delta P}{L}L + \left(\frac{Q_a}{A}\right)^2k_p\)
\(P_{pump} = \frac{\rho_lQh_pg}{\eta_p}, \quad E = \frac{P_{blower} + P_{pump}}{Q}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Water flow | m³/s |
| \(Q_a/Q\) | Air-to-water ratio | - |
| \(A\) | Tower cross-section | m² |
| \(\Delta P/L\) | Gas pressure drop per metre of packing | Pa/m |
| \(L\) | Packing depth | m |
| \(h_p\) | Pumping lift (to the top of the tower) | m |
| \(k_p\) | Loss coefficient for demister, support and ducts, N·s²/m⁴ | - |
| \(T\) | Air temperature | K |
| \(P_{amb}\) | Ambient pressure | Pa |
| \(\rho_g\) | Air density | kg/m³ |
| \(\rho_l\) | Water density | kg/m³ |
| \(\eta_b\) | Blower efficiency | - |
| \(\eta_p\) | Pump efficiency | - |
| \(Q_a\) | Air flow | m³/s |
| \(G_{me}\) | Air mass flow | kg/s |
| \(\Delta P_{losses}\) | Demister, support and duct losses | Pa |
| \(P_{in}\) | Blower discharge (tower inlet) pressure | Pa |
| \(P_{blower}\) | Blower brake power | W |
| \(P_{pump}\) | Pump brake power | W |
| \(P_{total}\) | Total power | W |
| \(E\) | Specific energy | J/m³ |
Method and standards
Adiabatic compression power and hydraulic lift for packed-tower aeration.
Where it is used
- Operating cost of VOC and radon strippers.
- Comparing tower designs.
Common mistakes
- Using the blower nameplate power.
- Forgetting demister and duct losses.
Assumptions and limits
- Adiabatic blower; atmospheric outlet.
Questions and answers
Why is the blower efficiency so low?
Small centrifugal blowers for strippers often run at 35–60 % efficiency; the pressure rise is small, so even modest losses matter.
How can energy be reduced?
A lower air-to-water ratio (if the removal allows), lower packing pressure drop or a larger tower diameter.
What do the defaults represent?
An illustrative case: Small radon stripper 0.01 m3/s, A/W 30, 0.8 m2, 100 Pa/m, 4 m. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 14-5, eqs. 14-60 to 14-63 and Example 14-6