Packed-Tower Air Stripping: Blower and Pump Power

Blower brake power from air flow and tower pressure drop, pump power to lift water to the top, total power and specific energy of packed-tower aeration.

Inputs

Examples: Small radon stripper 0.01 m3/s, A/W 30, 0.8 m2, 100 Pa/m, 4 mLarge VOC tower 0.4 m3/s, A/W 25, 15 m2, 80 Pa/m, 10 m

Accepted: 1E-5 to 10 m³/s
Accepted: 1 to 1,000
Accepted: 0.01 to 100 m²
Accepted: 1 to 1,000 Pa/m
Accepted: 0.1 to 50 m
Accepted: 0.1 to 60 m
Accepted: 0 to 2,000
Accepted: -23.15 to 56.85 °C
Accepted: 60 to 110 kPa
Accepted: 0.5 to 2 kg/m³
Accepted: 990 to 1,010 kg/m³
Accepted: 10 to 100 %
Accepted: 10 to 100 %

Results

Adiabatic blower equation with n_a = (γ − 1)/γ = 0.283 for air (molar mass 28.97). The pump term covers only the lift to the distributor; add pipe friction and any distributor pressure.

Air flow10.000m³/s
Air mass flow11.600kg/s
Demister, support and duct losses122.22Pa
Blower discharge (tower inlet) pressure98.922kPa
Blower brake power15.256kW
Pump brake power50.139kW
Total power65.394kW
Specific energy0.045413kWh/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Small radon stripper 0.01 m3/s, A/W 30, 0.8 m2, 100 Pa/m, 4 m. The inputs, in the units selected above:

InputValue
Water flow0.010000 m³/s
Air-to-water ratio30.000 -
Tower cross-section0.80000 m²
Gas pressure drop per metre of packing100.00 Pa/m
Packing depth4.0000 m
Pumping lift (to the top of the tower)4.5000 m
Loss coefficient for demister, support and ducts, N·s²/m⁴275.00 -
Air temperature15.000 °C
Ambient pressure101.33 kPa
Air density1.2250 kg/m³
Water density999.10 kg/m³
Blower efficiency50.000 %
Pump efficiency70.000 %

Applying the formula below gives:

ResultValue
Air flow0.30000 m³/s
Air mass flow0.36750 kg/s
Demister, support and duct losses38.672 Pa
Blower discharge (tower inlet) pressure101.76 kPa
Blower brake power0.26275 kW
Pump brake power0.62986 kW
Total power0.89261 kW
Specific energy0.024795 kWh/m³

Open this example in the calculator and change any input.

Formula

\(P_{blower} = \frac{G_{me}RT}{M\,n_a\eta_b}\left[\left(\frac{P_{in}}{P_{out}}\right)^{n_a} - 1\right], \quad P_{in} = P_{amb} + \frac{\Delta P}{L}L + \left(\frac{Q_a}{A}\right)^2k_p\)

\(P_{pump} = \frac{\rho_lQh_pg}{\eta_p}, \quad E = \frac{P_{blower} + P_{pump}}{Q}\)

Variables

Symbol Meaning SI unit
\(Q\) Water flow m³/s
\(Q_a/Q\) Air-to-water ratio -
\(A\) Tower cross-section m²
\(\Delta P/L\) Gas pressure drop per metre of packing Pa/m
\(L\) Packing depth m
\(h_p\) Pumping lift (to the top of the tower) m
\(k_p\) Loss coefficient for demister, support and ducts, N·s²/m⁴ -
\(T\) Air temperature K
\(P_{amb}\) Ambient pressure Pa
\(\rho_g\) Air density kg/m³
\(\rho_l\) Water density kg/m³
\(\eta_b\) Blower efficiency -
\(\eta_p\) Pump efficiency -
\(Q_a\) Air flow m³/s
\(G_{me}\) Air mass flow kg/s
\(\Delta P_{losses}\) Demister, support and duct losses Pa
\(P_{in}\) Blower discharge (tower inlet) pressure Pa
\(P_{blower}\) Blower brake power W
\(P_{pump}\) Pump brake power W
\(P_{total}\) Total power W
\(E\) Specific energy J/m³

Method and standards

Adiabatic compression power and hydraulic lift for packed-tower aeration.

Where it is used

  • Operating cost of VOC and radon strippers.
  • Comparing tower designs.

Common mistakes

  • Using the blower nameplate power.
  • Forgetting demister and duct losses.

Assumptions and limits

  • Adiabatic blower; atmospheric outlet.

Questions and answers

Why is the blower efficiency so low?

Small centrifugal blowers for strippers often run at 35–60 % efficiency; the pressure rise is small, so even modest losses matter.

How can energy be reduced?

A lower air-to-water ratio (if the removal allows), lower packing pressure drop or a larger tower diameter.

What do the defaults represent?

An illustrative case: Small radon stripper 0.01 m3/s, A/W 30, 0.8 m2, 100 Pa/m, 4 m. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 14-5, eqs. 14-60 to 14-63 and Example 14-6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.