FireCADCalc

Theis Well Drawdown (Non-Equilibrium) and Cooper–Jacob

Drawdown at a distance and time from a well pumping a confined aquifer, by the Theis well function and the Cooper–Jacob straight-line approximation.

Inputs

Examples: Illustrative: 2500 m3/d, T 600 m2/d, S 0.0002, r 50 m, 2 daysEarly time: same well, 500 m away after 2 hoursLow-transmissivity aquifer: 300 m3/d, T 50 m2/d, S 1e-4, r 20 m, 10 days

Accepted: 0.0036 to 36,000 m³/h
Accepted: 0.00864 to 86,400 m²/d
Accepted: 1E-7 to 0.5
Accepted: 0.01 to 100,000 m
Accepted: 0.00027778 to 277,780 h

Results

Theis: confined, homogeneous, infinite aquifer, fully penetrating well, constant rate, water released instantly from storage.

Well function argument r²S/(4Tt)2.0000e-05
Theis well function10.243
Drawdown (Theis)4.8905m
Drawdown (Cooper–Jacob)4.8905m
Cooper–Jacob drawdown per log cycle of time1.0994m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 2500 m3/d, T 600 m2/d, S 0.0002, r 50 m, 2 days. The inputs, in the units selected above:

InputValue
Pumping rate104.17 m³/h
Transmissivity600.00 m²/d
Storativity (storage coefficient)2.0000e-04 -
Distance from the well50.000 m
Time since pumping started48.000 h

Applying the formula below gives:

ResultValue
Well function argument r²S/(4Tt)1.0417e-04
Theis well function8.5924
Drawdown (Theis)2.8490 m
Drawdown (Cooper–Jacob)2.8490 m
Cooper–Jacob drawdown per log cycle of time0.76347 m

Open this example in the calculator and change any input.

Formula

\(s = \frac{Q}{4\pi T}W(u), \quad W(u) = \int_u^\infty \frac{e^{-x}}{x}dx = E_1(u), \quad u = \frac{r^2S}{4Tt}\)

\(s_{CJ} = \frac{Q}{4\pi T}\left(-0.5772 - \ln u\right)\)

Variables

Symbol Meaning SI unit
\(Q\) Pumping rate m³/s
\(T\) Transmissivity m²/s
\(S\) Storativity (storage coefficient) -
\(r\) Distance from the well m
\(t\) Time since pumping started s
\(u\) Well function argument r²S/(4Tt) -
\(W(u)\) Theis well function -
\(s\) Drawdown (Theis) m
\(s_{CJ}\) Drawdown (Cooper–Jacob) m
\(\Delta s\) Cooper–Jacob drawdown per log cycle of time m

Method and standards

Non-equilibrium radial flow to a well.

Where it is used

  • Pumping test interpretation and well field design.
  • Dewatering of excavations, interference between wells.

Common mistakes

  • Mixing units of days and seconds in T and t.
  • Using Cooper–Jacob at early times.

Assumptions and limits

  • Confined aquifer, Theis assumptions.

References

  • Theis non-equilibrium equation with the exponential integral; Cooper–Jacob approximation

Questions and answers

When does Cooper–Jacob work?

When u is small (below about 0.01–0.05), at long times or close to the well; the drawdown then plots as a straight line against log time.

How is a pumping test analysed?

Match the observed drawdown curve to W(u) or fit the Cooper–Jacob straight line; its slope per log cycle gives T = 2.3Q/(4πΔs).

What do the defaults represent?

An illustrative well pumping 2,500 m³/day from an aquifer with T = 600 m²/day and S = 0.0002, observed 50 m away after 2 days.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todd and Mays, Groundwater Hydrology, 3rd ed. (Wiley, 2005), sec. 4.6, Chow, Maidment and Mays, Applied Hydrology (McGraw-Hill, 1988), ch. 4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.