FireCADCalc

Drawdown Test: Permeability and Skin from the Semilog Slope

Permeability, skin factor and skin pressure drop from the semilog straight line of a constant-rate pressure drawdown test (slope and one-hour pressure).

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Gas-free oil well, 45 psi per cycleStimulated well, 8 psi per cycle

Accepted: 0.54344 to 543,440 bbl/d
Accepted: 1 to 3
Accepted: 0.01 to 1,000 cP
Accepted: 0.32808 to 1,640.4 ft
Accepted: 0.00014504 to 14,504 psi
Accepted: 14.504 to 14,504 psi
Accepted: 1.4504 to 14,504 psi
Accepted: 1 to 50 %
Accepted: 6.895E-8 to 0.0068948 1/psi
Accepted: 0.098425 to 1.6404 ft

Results

Use data after wellbore storage ends and before boundaries are felt (the middle-time straight line). Read p_1hr on the extrapolated line even if the measured point at 1 hour is still distorted by storage.

Permeability56.357mD
Skin factor3.8264
Pressure drop due to skin149.56psi
Radius reached by the pressure disturbance after 1 hour171.71ft

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Gas-free oil well, 45 psi per cycle. The inputs, in the units selected above:

InputValue
Constant oil rate during the test600.00 bbl/d
Oil formation volume factor1.3000 -
Oil viscosity0.80000 cP
Net pay thickness40.000 ft
Slope of the semilog straight line (per log cycle)45.000 psi
Initial reservoir pressure3,800.0 psi
Pressure on the straight line at 1 hour3,420.0 psi
Porosity18.000 %
Total compressibility1.4000e-05 1/psi
Wellbore radius0.35400 ft

Applying the formula below gives:

ResultValue
Permeability56.357 mD
Skin factor3.8264
Pressure drop due to skin149.56 psi
Radius reached by the pressure disturbance after 1 hour171.71 ft

Open this example in the calculator and change any input.

Formula

\(k = \frac{Q_oB_o\mu_o\ln10}{4\pi|m|h}, \quad s = 1.1513\left[\frac{p_i - p_{1hr}}{|m|} - \log\frac{4k(1\,\text{h})}{\gamma\phi\mu c_tr_w^2}\right], \quad \Delta p_{skin} = 0.869|m|s\)

Variables

Symbol Meaning SI unit
\(Q_o\) Constant oil rate during the test m³/s
\(B_o\) Oil formation volume factor -
\(\mu_o\) Oil viscosity Pa·s
\(h\) Net pay thickness m
\(|m|\) Slope of the semilog straight line (per log cycle) Pa
\(p_i\) Initial reservoir pressure Pa
\(p_{1hr}\) Pressure on the straight line at 1 hour Pa
\(\phi\) Porosity -
\(c_t\) Total compressibility 1/Pa
\(r_w\) Wellbore radius m
\(k\) Permeability m²
\(s\) Skin factor -
\(\Delta p_{skin}\) Pressure drop due to skin Pa
\(r_{inv}(1\,\text{h})\) Radius reached by the pressure disturbance after 1 hour m

Method and standards

Semilog drawdown analysis.

Where it is used

  • Well test interpretation.
  • Checking completion damage.

Common mistakes

  • Fitting the line through storage-dominated data.
  • Using a rate that varied during the test.

Assumptions and limits

  • Infinite-acting radial flow; constant rate.

Questions and answers

How does a drawdown test differ from a build-up?

The well flows at constant rate from shut-in conditions and the falling pressure is analysed; it gives the same k and s but needs a truly constant rate, which is hard to hold.

What is the radius of investigation?

How far the pressure disturbance has travelled, r ≈ √(4kt/φμc_t); it grows with the square root of time.

What do the defaults represent?

An illustrative case: Gas-free oil well, 45 psi per cycle. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, eqs. 6-170 to 6-174 and Example 6-24 (Earlougher's drawdown)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.