FireCADCalc

Average Permeability of Layers: Arithmetic, Harmonic, Geometric

Average permeability of up to five beds: thickness-weighted arithmetic for parallel flow, harmonic for beds in series, and geometric for random heterogeneity.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Four beds 4, 6, 2, 5 ft at 150, 60, 400, 25 mDFive equal 10 ft beds from 1 to 1000 mDTwo beds, a thin tight streak

Accepted: 0 to 984.25 ft
Accepted: 0.00010132 to 101,320 mD
Accepted: 0 to 984.25 ft
Accepted: 0.00010132 to 101,320 mD
Accepted: 0 to 984.25 ft
Accepted: 0.00010132 to 101,320 mD
Accepted: 0 to 984.25 ft
Accepted: 0.00010132 to 101,320 mD
Accepted: 0 to 984.25 ft
Accepted: 0.00010132 to 101,320 mD

Results

Arithmetic: horizontal flow through stacked layers (the usual reservoir case). Harmonic: flow across the layers, for example vertical flow or beds in series along the flow path. Geometric: random, uncorrelated heterogeneity. Σkh is in mD·ft.

Arithmetic (parallel beds, flow along the layers)110.88mD
Harmonic (beds in series, flow across them)51.256mD
Geometric (random heterogeneity)71.926mD
Total thickness17.000ft
Flow capacity Σkh1,885.0

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Four beds 4, 6, 2, 5 ft at 150, 60, 400, 25 mD. The inputs, in the units selected above:

InputValue
Layer 1 thickness (0 if unused)4.0000 ft
Layer 1 permeability150.00 mD
Layer 2 thickness (0 if unused)6.0000 ft
Layer 2 permeability60.000 mD
Layer 3 thickness (0 if unused)2.0000 ft
Layer 3 permeability400.00 mD
Layer 4 thickness (0 if unused)5.0000 ft
Layer 4 permeability25.000 mD
Layer 5 thickness (0 if unused)0 ft
Layer 5 permeability100.00 mD

Applying the formula below gives:

ResultValue
Arithmetic (parallel beds, flow along the layers)110.88 mD
Harmonic (beds in series, flow across them)51.256 mD
Geometric (random heterogeneity)71.926 mD
Total thickness17.000 ft
Flow capacity Σkh1,885.0

Open this example in the calculator and change any input.

Formula

\(k_{arith} = \frac{\sum k_ih_i}{\sum h_i}, \quad k_{harm} = \frac{\sum h_i}{\sum h_i/k_i}, \quad k_{geom} = \exp\left(\frac{\sum h_i\ln k_i}{\sum h_i}\right)\)

Variables

Symbol Meaning SI unit
\(h_1\) Layer 1 thickness (0 if unused) m
\(k_1\) Layer 1 permeability m²
\(h_2\) Layer 2 thickness (0 if unused) m
\(k_2\) Layer 2 permeability m²
\(h_3\) Layer 3 thickness (0 if unused) m
\(k_3\) Layer 3 permeability m²
\(h_4\) Layer 4 thickness (0 if unused) m
\(k_4\) Layer 4 permeability m²
\(h_5\) Layer 5 thickness (0 if unused) m
\(k_5\) Layer 5 permeability m²
\(k_{arith}\) Arithmetic (parallel beds, flow along the layers) m²
\(k_{harm}\) Harmonic (beds in series, flow across them) m²
\(k_{geom}\) Geometric (random heterogeneity) m²
\(h_t\) Total thickness m
\(\Sigma kh\) Flow capacity Σkh -

Method and standards

Permeability averaging.

Where it is used

  • Upscaling core data to layers.
  • Comparing core and well-test permeability.

Common mistakes

  • Using the arithmetic mean for vertical flow.
  • Averaging without thickness weighting.

Assumptions and limits

  • Uniform properties within each layer.

Questions and answers

Why can the averages differ so much?

The harmonic mean is dominated by the tightest layer and the arithmetic mean by the best; a single 1 mD bed in series can choke flow that parallel beds would carry easily.

Which one goes into a well test comparison?

The arithmetic (kh-weighted) value: a well test measures the total flow capacity Σkh of the layers it drains.

What do the defaults represent?

Four beds of 4, 6, 2 and 5 ft at 150, 60, 400 and 25 mD; the fifth layer is unused.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 4, eqs. 4-49 to 4-55 and Examples 4-11 to 4-13

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.