Worked example
Example: Water-wet sand, Sw = 0.5, nw 3, no 2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water saturation | 50.000 % |
| Connate water saturation | 20.000 % |
| Residual oil saturation to water | 25.000 % |
| Oil relative permeability at connate water | 0.90000 - |
| Water relative permeability at residual oil | 0.30000 - |
| Oil exponent | 2.0000 - |
| Water exponent | 3.0000 - |
| Capillary pressure at connate water | 8.0000 psi |
| Capillary pressure exponent | 1.0000 - |
| Oil viscosity | 5.0000 cP |
| Water viscosity | 0.60000 cP |
Applying the formula below gives:
| Result | Value |
|---|---|
| Oil relative permeability | 0.18595 |
| Water relative permeability | 0.048685 |
| Oil–water capillary pressure | 3.6364 psi |
| Water cut, horizontal flow | 68.571 % |
| End-point mobility ratio | 2.7778 |
Open this example in the calculator and change any input.
Formula
\(k_{ro} = (k_{ro})_{S_{wc}}\left(\frac{1 - S_w - S_{orw}}{1 - S_{wc} - S_{orw}}\right)^{n_o}, \quad k_{rw} = (k_{rw})_{S_{orw}}\left(\frac{S_w - S_{wc}}{1 - S_{wc} - S_{orw}}\right)^{n_w}, \quad p_c = (p_c)_{S_{wc}}\left(\frac{1 - S_w - S_{orw}}{1 - S_{wc} - S_{orw}}\right)^{n_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S_w\) | Water saturation | - |
| \(S_{wc}\) | Connate water saturation | - |
| \(S_{orw}\) | Residual oil saturation to water | - |
| \((k_{ro})_{S_{wc}}\) | Oil relative permeability at connate water | - |
| \((k_{rw})_{S_{orw}}\) | Water relative permeability at residual oil | - |
| \(n_o\) | Oil exponent | - |
| \(n_w\) | Water exponent | - |
| \((p_c)_{S_{wc}}\) | Capillary pressure at connate water | Pa |
| \(n_p\) | Capillary pressure exponent | - |
| \(\mu_o\) | Oil viscosity | Pa·s |
| \(\mu_w\) | Water viscosity | Pa·s |
| \(k_{ro}\) | Oil relative permeability | - |
| \(k_{rw}\) | Water relative permeability | - |
| \(p_{cwo}\) | Oil–water capillary pressure | Pa |
| \(f_w\) | Water cut, horizontal flow | - |
| \(M\) | End-point mobility ratio | - |
Method and standards
Corey-type analytic relative permeability.
Where it is used
- Simulation input from limited core data.
- Waterflood screening.
Common mistakes
- Mixing drainage and imbibition curves.
- Using end points from a different rock type.
Assumptions and limits
- Two-phase oil–water system.
Questions and answers
What do the exponents mean?
They set the curvature: larger exponents make a phase lose mobility quickly as its saturation falls. Water-wet rocks often have n_w ≈ 3–4 and n_o ≈ 2.
Why is the oil end point below 1?
It is the oil relative permeability at connate water, relative to absolute permeability; the water present reduces oil flow.
What do the defaults represent?
An illustrative case: Water-wet sand, Sw = 0.5, nw 3, no 2. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 5, eqs. 5-22 to 5-24 and Example 5-5 (Corey-type analytic relative permeability)