FireCADCalc

Oil–Water Relative Permeability and Capillary Pressure (Corey Form)

Oil and water relative permeability and capillary pressure at a water saturation from Corey-type end points and exponents, with water cut and mobility ratio.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Water-wet sand, Sw = 0.5, nw 3, no 2

Accepted: 0 to 100 %
Accepted: 0 to 80 %
Accepted: 0 to 80 %
Accepted: 0.01 to 1
Accepted: 0.01 to 1
Accepted: 0.5 to 8
Accepted: 0.5 to 8
Accepted: 0 to 1,450.4 psi
Accepted: 0.1 to 5
Accepted: 0.01 to 10,000 cP
Accepted: 0.01 to 1,000 cP

Results

These analytic forms are what simulators use to represent laboratory curves; fit the end points and exponents to core data. M above 1 means water is more mobile than the oil it displaces: an unfavourable flood.

Oil relative permeability0.18595
Water relative permeability0.048685
Oil–water capillary pressure3.6364psi
Water cut, horizontal flow68.571%
End-point mobility ratio2.7778

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water-wet sand, Sw = 0.5, nw 3, no 2. The inputs, in the units selected above:

InputValue
Water saturation50.000 %
Connate water saturation20.000 %
Residual oil saturation to water25.000 %
Oil relative permeability at connate water0.90000 -
Water relative permeability at residual oil0.30000 -
Oil exponent2.0000 -
Water exponent3.0000 -
Capillary pressure at connate water8.0000 psi
Capillary pressure exponent1.0000 -
Oil viscosity5.0000 cP
Water viscosity0.60000 cP

Applying the formula below gives:

ResultValue
Oil relative permeability0.18595
Water relative permeability0.048685
Oil–water capillary pressure3.6364 psi
Water cut, horizontal flow68.571 %
End-point mobility ratio2.7778

Open this example in the calculator and change any input.

Formula

\(k_{ro} = (k_{ro})_{S_{wc}}\left(\frac{1 - S_w - S_{orw}}{1 - S_{wc} - S_{orw}}\right)^{n_o}, \quad k_{rw} = (k_{rw})_{S_{orw}}\left(\frac{S_w - S_{wc}}{1 - S_{wc} - S_{orw}}\right)^{n_w}, \quad p_c = (p_c)_{S_{wc}}\left(\frac{1 - S_w - S_{orw}}{1 - S_{wc} - S_{orw}}\right)^{n_p}\)

Variables

Symbol Meaning SI unit
\(S_w\) Water saturation -
\(S_{wc}\) Connate water saturation -
\(S_{orw}\) Residual oil saturation to water -
\((k_{ro})_{S_{wc}}\) Oil relative permeability at connate water -
\((k_{rw})_{S_{orw}}\) Water relative permeability at residual oil -
\(n_o\) Oil exponent -
\(n_w\) Water exponent -
\((p_c)_{S_{wc}}\) Capillary pressure at connate water Pa
\(n_p\) Capillary pressure exponent -
\(\mu_o\) Oil viscosity Pa·s
\(\mu_w\) Water viscosity Pa·s
\(k_{ro}\) Oil relative permeability -
\(k_{rw}\) Water relative permeability -
\(p_{cwo}\) Oil–water capillary pressure Pa
\(f_w\) Water cut, horizontal flow -
\(M\) End-point mobility ratio -

Method and standards

Corey-type analytic relative permeability.

Where it is used

  • Simulation input from limited core data.
  • Waterflood screening.

Common mistakes

  • Mixing drainage and imbibition curves.
  • Using end points from a different rock type.

Assumptions and limits

  • Two-phase oil–water system.

Questions and answers

What do the exponents mean?

They set the curvature: larger exponents make a phase lose mobility quickly as its saturation falls. Water-wet rocks often have n_w ≈ 3–4 and n_o ≈ 2.

Why is the oil end point below 1?

It is the oil relative permeability at connate water, relative to absolute permeability; the water present reduces oil flow.

What do the defaults represent?

An illustrative case: Water-wet sand, Sw = 0.5, nw 3, no 2. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 5, eqs. 5-22 to 5-24 and Example 5-5 (Corey-type analytic relative permeability)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.