Worked example
Example: Thick column, low rate, M = 0.8. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oil rate | 120.00 bbl/d |
| Oil column thickness | 80.000 ft |
| Perforated interval | 20.000 ft |
| Water density | 64.000 lb/ft³ |
| Oil density | 50.000 lb/ft³ |
| Oil viscosity | 1.5000 cP |
| Oil formation volume factor | 1.2000 - |
| Horizontal permeability | 200.00 mD |
| Vertical permeability | 40.000 mD |
| Porosity | 20.000 % |
| Water-oil mobility ratio | 0.80000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dimensionless cone height | 3.0613 |
| Dimensionless breakthrough time (Sobocinski–Cornelius) | 8.1250 |
| Time to breakthrough (Sobocinski–Cornelius) | 3,735.9 d |
| Dimensionless breakthrough time (Bournazel–Jeanson) | 3.5719 |
| Time to breakthrough (Bournazel–Jeanson) | 1,642.4 d |
| Critical rate (Sobocinski–Cornelius) | 105.28 bbl/d |
| Critical rate (Bournazel–Jeanson) | 85.717 bbl/d |
Open this example in the calculator and change any input.
Formula
\(Z = \frac{0.492\times10^{-4}\Delta\rho\,k_hh(h - h_p)}{\mu_oB_oQ_o}, \quad (t_D)_{BT} = \frac{4Z + 1.75Z^2 - 0.75Z^3}{7 - 2Z}\ \text{or}\ \frac{Z}{3 - 0.7Z}, \quad t_{BT} = \frac{20{,}325\mu_oh\phi(t_D)_{BT}}{\Delta\rho\,k_v(1 + M^\alpha)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_o\) | Oil rate | m³/s |
| \(h\) | Oil column thickness | m |
| \(h_p\) | Perforated interval | m |
| \(\rho_w\) | Water density | kg/m³ |
| \(\rho_o\) | Oil density | kg/m³ |
| \(\mu_o\) | Oil viscosity | Pa·s |
| \(B_o\) | Oil formation volume factor | - |
| \(k_h\) | Horizontal permeability | m² |
| \(k_v\) | Vertical permeability | m² |
| \(\phi\) | Porosity | - |
| \(M\) | Water-oil mobility ratio | - |
| \(Z\) | Dimensionless cone height | - |
| \((t_D)_{BT,SC}\) | Dimensionless breakthrough time (Sobocinski–Cornelius) | - |
| \(t_{BT,SC}\) | Time to breakthrough (Sobocinski–Cornelius) | s |
| \((t_D)_{BT,BJ}\) | Dimensionless breakthrough time (Bournazel–Jeanson) | - |
| \(t_{BT,BJ}\) | Time to breakthrough (Bournazel–Jeanson) | s |
| \(Q_{oc,SC}\) | Critical rate (Sobocinski–Cornelius) | m³/s |
| \(Q_{oc,BJ}\) | Critical rate (Bournazel–Jeanson) | m³/s |
Method and standards
Sobocinski–Cornelius and Bournazel–Jeanson (field units).
Where it is used
- Completion and rate planning in bottom-water reservoirs.
- Comparing vertical and horizontal wells.
Common mistakes
- Using k_h instead of k_v in the time equation.
- Measuring h_p from the bottom.
Assumptions and limits
- Homogeneous anisotropic reservoir; constant rate.
Questions and answers
Why does vertical permeability control breakthrough?
The cone grows by vertical flow of water up toward the perforations; low k_v slows it down.
What does Z ≥ 3.5 mean?
At that dimensionless cone height the cone is stable and never reaches the well; the rate that gives Z = 3.5 is the critical rate.
What do the defaults represent?
An illustrative case: Thick column, low rate, M = 0.8. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 9, eqs. 9-21 to 9-27 and Examples 9-11 to 9-13