Worked example
Example: Field with water production. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oil rate (stock tank) | 8,500.0 bbl/d |
| Oil formation volume factor | 1.2500 - |
| Producing gas-oil ratio | 650.00 scf/STB |
| Solution gas-oil ratio | 520.00 scf/STB |
| Gas formation volume factor | 0.001100 bbl/scf |
| Water rate (stock tank) | 3,000.0 bbl/d |
| Water formation volume factor | 1.0200 - |
| Initial reservoir pressure | 2,800.0 psi |
| Stabilised reservoir pressure | 2,450.0 psi |
| Time at this pressure drop (for cumulative influx) | 180.00 d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water influx rate (reservoir voidage) | 14,901 bbl/d |
| Water influx constant | 42.573 bbl/(d·psi) |
| Cumulative influx over the time at this drop | 2,682,090 bbl |
Open this example in the calculator and change any input.
Formula
\(e_w = Q_oB_o + (GOR - R_s)Q_oB_g + Q_wB_w, \quad C = \frac{e_w}{p_i - p}, \quad W_e = C\int(p_i - p)\,dt\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_o\) | Oil rate (stock tank) | m³/s |
| \(B_o\) | Oil formation volume factor | - |
| \(GOR\) | Producing gas-oil ratio | m³/m³ |
| \(R_s\) | Solution gas-oil ratio | m³/m³ |
| \(B_g\) | Gas formation volume factor | m³/m³ |
| \(Q_w\) | Water rate (stock tank) | m³/s |
| \(B_w\) | Water formation volume factor | - |
| \(p_i\) | Initial reservoir pressure | Pa |
| \(p\) | Stabilised reservoir pressure | Pa |
| \(t\) | Time at this pressure drop (for cumulative influx) | s |
| \(e_w\) | Water influx rate (reservoir voidage) | m³/s |
| \(C\) | Water influx constant | m³/(s·Pa) |
| \(W_e\) | Cumulative influx over the time at this drop | m³ |
Method and standards
Schilthuis steady-state aquifer.
Where it is used
- Water-drive reservoir studies.
- Checking aquifer models against history.
Common mistakes
- Using a pressure that is not stabilised.
- Mixing reservoir and stock-tank volumes.
Assumptions and limits
- Steady-state aquifer flow; stabilised pressure.
Questions and answers
Why does voidage equal influx?
If the reservoir pressure is steady, whatever leaves the pore space (oil, free gas, water) must be replaced by water coming in.
What is free gas production?
Gas produced above the solution gas, (GOR − R_s)Q_o, occupying B_g reservoir barrels per scf.
What do the defaults represent?
An illustrative case: Field with water production. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 10, eqs. 10-1, 10-8 to 10-10 and Example 10-3