Worked example
Example: Sw 0.55, 3 cP oil, 5 degrees up-dip. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oil relative permeability at the saturation | 0.30000 - |
| Water relative permeability at the saturation | 0.12000 - |
| Oil viscosity | 3.0000 cP |
| Water viscosity | 0.50000 cP |
| Absolute permeability | 50.000 mD |
| Cross-sectional area of the flood | 25,000 ft² |
| Water injection rate (reservoir) | 1,000.0 bbl/d |
| Water density | 64.000 lb/ft³ |
| Oil density | 45.000 lb/ft³ |
| Dip angle (positive: injector down-dip, flood moving up-dip) | 5.0000 ° |
| Oil formation volume factor | 1.2000 - |
| Water formation volume factor | 1.0500 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water cut, horizontal (no gravity) | 70.588 % |
| Water cut with gravity (reservoir) | 70.474 % |
| Oil cut (reservoir) | 29.526 % |
| Water-oil ratio (reservoir) | 2.3868 |
| Water-oil ratio (surface) | 2.7278 |
| Surface water cut | 73.175 % |
Open this example in the calculator and change any input.
Formula
\(f_w = \frac{1 - \frac{kk_{ro}A}{\mu_oi_w}(\rho_w - \rho_o)g\sin\alpha}{1 + \frac{k_{ro}}{k_{rw}}\frac{\mu_w}{\mu_o}}, \quad WOR_s = \frac{B_of_w}{B_w(1 - f_w)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k_{ro}\) | Oil relative permeability at the saturation | - |
| \(k_{rw}\) | Water relative permeability at the saturation | - |
| \(\mu_o\) | Oil viscosity | Pa·s |
| \(\mu_w\) | Water viscosity | Pa·s |
| \(k\) | Absolute permeability | m² |
| \(A\) | Cross-sectional area of the flood | m² |
| \(i_w\) | Water injection rate (reservoir) | m³/s |
| \(\rho_w\) | Water density | kg/m³ |
| \(\rho_o\) | Oil density | kg/m³ |
| \(\alpha\) | Dip angle (positive: injector down-dip, flood moving up-dip) | rad |
| \(B_o\) | Oil formation volume factor | - |
| \(B_w\) | Water formation volume factor | - |
| \(f_{w,0}\) | Water cut, horizontal (no gravity) | - |
| \(f_w\) | Water cut with gravity (reservoir) | - |
| \(f_o\) | Oil cut (reservoir) | - |
| \(WOR_r\) | Water-oil ratio (reservoir) | - |
| \(WOR_s\) | Water-oil ratio (surface) | - |
| \(f_{ws}\) | Surface water cut | - |
Method and standards
Fractional flow equation (Leverett).
Where it is used
- Waterflood design and forecasts.
- Choosing injection direction and rate.
Common mistakes
- Using stock-tank instead of reservoir rates.
- Using the wrong sign of the dip.
Assumptions and limits
- Linear displacement; capillary pressure neglected.
Questions and answers
Why does oil viscosity matter so much?
Water cut depends on the mobility ratio; a viscous oil lets water finger through, so the cut rises early and recovery at breakthrough falls.
Is the gravity effect large?
Usually a few per cent at normal injection rates; it matters at low rates and steep dips.
What do the defaults represent?
An illustrative case: Sw 0.55, 3 cP oil, 5 degrees up-dip. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 14, eqs. 14-22 to 14-31 and Examples 14-5 and 14-6