Worked example
Example: Horizontal liquid, 80 mD, 1.5 cP, 1500 ft. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fluid | Liquid (slightly compressible) |
| Permeability | 80.000 mD |
| Cross-sectional area | 5,000.0 ft² |
| Length | 1,500.0 ft |
| Viscosity | 1.5000 cP |
| Upstream pressure | 2,500.0 psi |
| Downstream pressure | 2,480.0 psi |
| Porosity | 18.000 % |
| Liquid density (liquid) | 50.000 lb/ft³ |
| Dip of the flow path, positive upward (liquid) | 0 ° |
| Temperature (gas) | 150.00 °F |
| Gas Z at the mean pressure (gas) | 0.85000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flow rate at reservoir conditions (liquid) or at the mean pressure (gas) | 4.0075 bbl/d |
| Gas rate at standard conditions (gas) | 0 Mscf/d |
| Apparent (Darcy) velocity | 5.2085e-08 ft/s |
| Actual (interstitial) velocity | 2.8936e-07 ft/s |
| Mean pressure (gas) | 2,490.0 psi |
Open this example in the calculator and change any input.
Formula
\(q = \frac{kA[(p_1 - p_2) - \rho gL\sin\alpha]}{\mu L}, \quad Q_{sc} = \frac{kA\,T_{sc}(p_1^2 - p_2^2)}{2p_{sc}TZ\mu L}, \quad v = \frac{q}{\phi A}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{fluid}\) | Fluid | - |
| \(k\) | Permeability | m² |
| \(A\) | Cross-sectional area | m² |
| \(L\) | Length | m |
| \(\mu\) | Viscosity | Pa·s |
| \(p_1\) | Upstream pressure | Pa |
| \(p_2\) | Downstream pressure | Pa |
| \(\phi\) | Porosity | - |
| \(\rho\) | Liquid density (liquid) | kg/m³ |
| \(\alpha\) | Dip of the flow path, positive upward (liquid) | rad |
| \(T\) | Temperature (gas) | K |
| \(Z\) | Gas Z at the mean pressure (gas) | - |
| \(q\) | Flow rate at reservoir conditions (liquid) or at the mean pressure (gas) | m³/s |
| \(Q_{sc}\) | Gas rate at standard conditions (gas) | Nm³/s |
| \(u\) | Apparent (Darcy) velocity | m/s |
| \(v\) | Actual (interstitial) velocity | m/s |
| \(\bar p\) | Mean pressure (gas) | Pa |
Method and standards
Darcy's law, linear geometry.
Where it is used
- Core flooding and laboratory permeability.
- Flow between wells in a channel sand.
Common mistakes
- Ignoring gravity in dipping beds.
- Using gas properties at one end instead of the mean.
Assumptions and limits
- Laminar, single-phase, homogeneous medium.
Questions and answers
Why is the actual velocity higher than the Darcy velocity?
Fluid moves only through the pores, a fraction φ of the area; the interstitial velocity is the Darcy velocity divided by porosity.
How does dip change the rate?
Flow follows the potential p − ρgz, not the pressure alone; flowing up-dip costs ρgL sin α of the pressure difference.
What do the defaults represent?
An illustrative case: Horizontal liquid, 80 mD, 1.5 cP, 1500 ft. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, eqs. 6-14 to 6-24 and Examples 6-1, 6-2 and 6-4