Worked example
Example: Pseudo-steady, skin 3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Permeability | 50.000 mD |
| Net pay thickness | 12.192 m |
| Reservoir pressure (average or at the drainage boundary) | 3,000.0 psi |
| Flowing bottom-hole pressure | 2,000.0 psi |
| Oil viscosity | 1.2000 cP |
| Oil formation volume factor | 1.3000 - |
| Drainage radius | 304.80 m |
| Wellbore radius | 0.091440 m |
| Skin factor | 3.0000 - |
| Flow regime | Pseudo-steady state (average pressure) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Oil rate (stock tank) | 876.24 bbl/d |
| Productivity index | 2.3386e-10 |
| Productivity index (stock-tank m³/d per bar) | 2.0205 |
Open this example in the calculator and change any input.
Formula
\(q_o = \frac{2\pi kh(\bar p - p_{wf})}{\mu_oB_o\left[\ln\frac{r_e}{r_w} - 0.75 + s\right]}\ \text{(pseudo-steady)}, \quad J = \frac{q_o}{\bar p - p_{wf}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k\) | Permeability | m² |
| \(h\) | Net pay thickness | m |
| \(\bar p\) | Reservoir pressure (average or at the drainage boundary) | Pa |
| \(p_{wf}\) | Flowing bottom-hole pressure | Pa |
| \(\mu_o\) | Oil viscosity | Pa·s |
| \(B_o\) | Oil formation volume factor | - |
| \(r_e\) | Drainage radius | m |
| \(r_w\) | Wellbore radius | m |
| \(s\) | Skin factor | - |
| \(\text{regime}\) | Flow regime | - |
| \(q_o\) | Oil rate (stock tank) | m³/s |
| \(J\) | Productivity index | - |
Method and standards
Darcy's law for radial flow in SI units.
Where it is used
- Well test interpretation and rate forecasts.
- Artificial-lift design.
Common mistakes
- Using it below the bubble point.
- Ignoring skin.
Assumptions and limits
- Single-phase, homogeneous, radial drainage.
Questions and answers
What does skin mean?
Extra pressure drop near the well: positive for damage, negative for stimulation such as acidising or fractures.
Steady or pseudo-steady state?
Steady state holds with pressure support at the boundary (water drive); pseudo-steady state for a closed drainage area, using average pressure.
What do the defaults represent?
An illustrative case: Pseudo-steady, skin 3. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, eqs. 6-27 and 6-149 (radial flow, skin)