FireCADCalc

Gas–Oil Relative Permeability and Capillary Pressure (Corey Form)

Oil and gas relative permeability and gas–oil capillary pressure at a gas saturation from end points, critical saturations and exponents (Corey-type).

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Solution-gas drive sand, Sg = 0.12

Accepted: 0 to 100 %
Accepted: 0 to 80 %
Accepted: 0 to 80 %
Accepted: 0 to 30 %
Accepted: 0.01 to 1
Accepted: 0.01 to 1
Accepted: 0.3 to 8
Accepted: 0.3 to 8
Accepted: 0 to 1,450.4 psi
Accepted: 0.1 to 5

Results

Gas does not flow until its saturation exceeds the critical value S_gc; oil stops flowing at the critical liquid saturation S_wc + S_org. Solution-gas drive recovery depends strongly on the k_rg/k_ro ratio these curves give.

Oil relative permeability0.58460
Gas relative permeability0.005620
Gas–oil capillary pressure1.5707psi
Critical (total) liquid saturation35.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Solution-gas drive sand, Sg = 0.12. The inputs, in the units selected above:

InputValue
Gas saturation12.000 %
Connate water saturation20.000 %
Residual oil saturation to gas15.000 %
Critical gas saturation3.0000 %
Oil relative permeability at critical gas0.80000 -
Gas relative permeability at connate water0.70000 -
Oil exponent2.0000 -
Gas exponent2.5000 -
Capillary pressure at critical liquid saturation5.0000 psi
Capillary pressure exponent0.60000 -

Applying the formula below gives:

ResultValue
Oil relative permeability0.58460
Gas relative permeability0.005620
Gas–oil capillary pressure1.5707 psi
Critical (total) liquid saturation35.000 %

Open this example in the calculator and change any input.

Formula

\(k_{ro} = (k_{ro})_{S_{gc}}\left(\frac{1 - S_g - S_{lc}}{1 - S_{gc} - S_{lc}}\right)^{n_{go}}, \quad k_{rg} = (k_{rg})_{S_{wc}}\left(\frac{S_g - S_{gc}}{1 - S_{lc} - S_{gc}}\right)^{n_g}, \quad S_{lc} = S_{wc} + S_{org}\)

Variables

Symbol Meaning SI unit
\(S_g\) Gas saturation -
\(S_{wc}\) Connate water saturation -
\(S_{org}\) Residual oil saturation to gas -
\(S_{gc}\) Critical gas saturation -
\((k_{ro})_{S_{gc}}\) Oil relative permeability at critical gas -
\((k_{rg})_{S_{wc}}\) Gas relative permeability at connate water -
\(n_{go}\) Oil exponent -
\(n_g\) Gas exponent -
\((p_c)_{S_{lc}}\) Capillary pressure at critical liquid saturation Pa
\(n_{pg}\) Capillary pressure exponent -
\(k_{ro}\) Oil relative permeability -
\(k_{rg}\) Gas relative permeability -
\(p_{cgo}\) Gas–oil capillary pressure Pa
\(S_{lc}\) Critical (total) liquid saturation -

Method and standards

Corey-type analytic gas–oil relative permeability.

Where it is used

  • Simulation input.
  • Gas-cap and solution-gas drive studies.

Common mistakes

  • Taking S_gc as zero.
  • Using oil–water end points for gas–oil.

Assumptions and limits

  • Gas–oil system at connate water.

Questions and answers

Why does the gas-oil ratio climb in solution-gas drive?

Once gas exceeds its critical saturation k_rg rises steeply while k_ro falls, so the producing GOR increases rapidly.

What is the critical liquid saturation?

Connate water plus residual oil to gas; below it no liquid can flow.

What do the defaults represent?

An illustrative case: Solution-gas drive sand, Sg = 0.12. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 5, eqs. 5-25 to 5-27 and Example 5-5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.