Worked example
Example: Solution-gas drive sand, Sg = 0.12. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas saturation | 12.000 % |
| Connate water saturation | 20.000 % |
| Residual oil saturation to gas | 15.000 % |
| Critical gas saturation | 3.0000 % |
| Oil relative permeability at critical gas | 0.80000 - |
| Gas relative permeability at connate water | 0.70000 - |
| Oil exponent | 2.0000 - |
| Gas exponent | 2.5000 - |
| Capillary pressure at critical liquid saturation | 5.0000 psi |
| Capillary pressure exponent | 0.60000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Oil relative permeability | 0.58460 |
| Gas relative permeability | 0.005620 |
| Gas–oil capillary pressure | 1.5707 psi |
| Critical (total) liquid saturation | 35.000 % |
Open this example in the calculator and change any input.
Formula
\(k_{ro} = (k_{ro})_{S_{gc}}\left(\frac{1 - S_g - S_{lc}}{1 - S_{gc} - S_{lc}}\right)^{n_{go}}, \quad k_{rg} = (k_{rg})_{S_{wc}}\left(\frac{S_g - S_{gc}}{1 - S_{lc} - S_{gc}}\right)^{n_g}, \quad S_{lc} = S_{wc} + S_{org}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S_g\) | Gas saturation | - |
| \(S_{wc}\) | Connate water saturation | - |
| \(S_{org}\) | Residual oil saturation to gas | - |
| \(S_{gc}\) | Critical gas saturation | - |
| \((k_{ro})_{S_{gc}}\) | Oil relative permeability at critical gas | - |
| \((k_{rg})_{S_{wc}}\) | Gas relative permeability at connate water | - |
| \(n_{go}\) | Oil exponent | - |
| \(n_g\) | Gas exponent | - |
| \((p_c)_{S_{lc}}\) | Capillary pressure at critical liquid saturation | Pa |
| \(n_{pg}\) | Capillary pressure exponent | - |
| \(k_{ro}\) | Oil relative permeability | - |
| \(k_{rg}\) | Gas relative permeability | - |
| \(p_{cgo}\) | Gas–oil capillary pressure | Pa |
| \(S_{lc}\) | Critical (total) liquid saturation | - |
Method and standards
Corey-type analytic gas–oil relative permeability.
Where it is used
- Simulation input.
- Gas-cap and solution-gas drive studies.
Common mistakes
- Taking S_gc as zero.
- Using oil–water end points for gas–oil.
Assumptions and limits
- Gas–oil system at connate water.
Questions and answers
Why does the gas-oil ratio climb in solution-gas drive?
Once gas exceeds its critical saturation k_rg rises steeply while k_ro falls, so the producing GOR increases rapidly.
What is the critical liquid saturation?
Connate water plus residual oil to gas; below it no liquid can flow.
What do the defaults represent?
An illustrative case: Solution-gas drive sand, Sg = 0.12. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 5, eqs. 5-25 to 5-27 and Example 5-5