FireCADCalc

Reservoir Drive Indices: Depletion, Gas Cap, Water and Expansion

Water influx from the material balance and the depletion, segregation (gas-cap), water and rock-fluid expansion drive indices of a combination-drive oil reservoir.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: No gas cap, strong aquiferModerate gas cap, partial water drive

Accepted: 6.29E-6 to 6,289,800 MMbbl
Accepted: 0 to 10
Accepted: 0 to 6,289,800 MMbbl
Accepted: 0 to 112,290 scf/STB
Accepted: 0 to 6.29E+12 bbl
Accepted: 1 to 10
Accepted: 1 to 10
Accepted: 0 to 112,290 scf/STB
Accepted: 1.781E-6 to 0.17811 bbl/scf
Accepted: 1.781E-6 to 0.17811 bbl/scf
Accepted: 0.9 to 1.2
Accepted: 0 to 90 %
Accepted: 0 to 0.0068948 1/psi
Accepted: 0 to 0.0068948 1/psi
Accepted: 0 to 14,504 psi

Results

The four indices add up to 1. Keep the depletion-drive index low: it is the least efficient mechanism.

Cumulative water influx9,894,160bbl
Net water influx8,364,160bbl
Depletion-drive index21.858%
Segregation (gas-cap) drive index0%
Water-drive index76.176%
Rock and fluid expansion index1.9658%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: No gas cap, strong aquifer. The inputs, in the units selected above:

InputValue
Initial oil in place (stock tank)40.000 MMbbl
Gas-cap to oil volume ratio0 -
Cumulative oil produced6.0000 MMbbl
Cumulative produced gas-oil ratio900.00 scf/STB
Cumulative water produced1,500,000 bbl
Two-phase formation volume factor now1.4800 -
Initial two-phase (= oil) formation volume factor1.4200 -
Initial solution gas-oil ratio650.00 scf/STB
Gas formation volume factor now0.001400 bbl/scf
Initial gas formation volume factor0.001100 bbl/scf
Water formation volume factor1.0200 -
Initial water saturation25.000 %
Water compressibility3.0000e-06 1/psi
Pore compressibility4.0000e-06 1/psi
Pressure drop600.00 psi

Applying the formula below gives:

ResultValue
Cumulative water influx9,894,160 bbl
Net water influx8,364,160 bbl
Depletion-drive index21.858 %
Segregation (gas-cap) drive index0 %
Water-drive index76.176 %
Rock and fluid expansion index1.9658 %

Open this example in the calculator and change any input.

Formula

\(A = N_p[B_t + (R_p - R_{si})B_g], \quad DDI = \frac{N(B_t - B_{ti})}{A}, \quad SDI = \frac{NmB_{ti}(B_g - B_{gi})/B_{gi}}{A}, \quad WDI = \frac{W_e - W_pB_w}{A}\)

Variables

Symbol Meaning SI unit
\(N\) Initial oil in place (stock tank) m³
\(m\) Gas-cap to oil volume ratio -
\(N_p\) Cumulative oil produced m³
\(R_p\) Cumulative produced gas-oil ratio m³/m³
\(W_p\) Cumulative water produced m³
\(B_t\) Two-phase formation volume factor now -
\(B_{ti}\) Initial two-phase (= oil) formation volume factor -
\(R_{si}\) Initial solution gas-oil ratio m³/m³
\(B_g\) Gas formation volume factor now m³/m³
\(B_{gi}\) Initial gas formation volume factor m³/m³
\(B_w\) Water formation volume factor -
\(S_{wi}\) Initial water saturation -
\(c_w\) Water compressibility 1/Pa
\(c_f\) Pore compressibility 1/Pa
\(p_i - p\) Pressure drop Pa
\(W_e\) Cumulative water influx m³
\(W_e - W_pB_w\) Net water influx m³
\(DDI\) Depletion-drive index -
\(SDI\) Segregation (gas-cap) drive index -
\(WDI\) Water-drive index -
\(EDI\) Rock and fluid expansion index -

Method and standards

Material-balance drive indices.

Where it is used

  • Reservoir management reviews.
  • Choosing pressure maintenance.

Common mistakes

  • Using B_o instead of B_t below the bubble point.
  • Leaving out the gas cap's initial size.

Assumptions and limits

  • Tank model; uniform pressure.

Questions and answers

Where does the water influx come from?

It is what the material balance needs to close: withdrawal minus oil, gas-cap and rock expansion, plus the water produced.

Why is the expansion index small here?

Once a gas cap or free gas exists, gas expansion dwarfs the compressibility of water and rock.

What do the defaults represent?

An illustrative case: No gas cap, strong aquifer. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 11, eqs. 11-17 to 11-23 and Example 11-1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.