Worked example
Example: Oil well 400 STB/d, 0.3 ft wellbore, after 5 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oil rate (stock tank) | 400.00 bbl/d |
| Oil formation volume factor | 1.2000 - |
| Oil viscosity | 1.2000 cP |
| Permeability | 80.000 mD |
| Net pay thickness | 20.000 ft |
| Porosity | 18.000 % |
| Total compressibility | 1.0000e-05 1/psi |
| Initial reservoir pressure | 3,800.0 psi |
| Radius from the well (the wellbore radius for p_wf) | 0.30000 ft |
| Time since the start of flow | 5.0000 h |
| Drainage area (for the stabilisation time) | 60.000 acre |
Applying the formula below gives:
| Result | Value |
|---|---|
| Argument x = φμc_tr²/(4kt) | 4.6079e-07 |
| Exponential integral E₁(x) | 14.013 |
| Pressure at r and t | 3,443.8 psi |
| Pressure drop | 356.17 psi |
| Pressure by the log approximation | 3,443.8 psi |
| Time to pseudo-steady state (circular area) | 26.763 h |
Open this example in the calculator and change any input.
Formula
\(p(r,t) = p_i - \frac{q_oB_o\mu_o}{4\pi kh}E_1(x), \quad x = \frac{\phi\mu c_t r^2}{4kt}, \quad E_1(x) \approx -\ln(1.781x)\ (x < 0.01), \quad t_{pss} = 0.1\frac{\phi\mu c_tA}{k}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q_o\) | Oil rate (stock tank) | m³/s |
| \(B_o\) | Oil formation volume factor | - |
| \(\mu_o\) | Oil viscosity | Pa·s |
| \(k\) | Permeability | m² |
| \(h\) | Net pay thickness | m |
| \(\phi\) | Porosity | - |
| \(c_t\) | Total compressibility | 1/Pa |
| \(p_i\) | Initial reservoir pressure | Pa |
| \(r\) | Radius from the well (the wellbore radius for p_wf) | m |
| \(t\) | Time since the start of flow | s |
| \(A\) | Drainage area (for the stabilisation time) | m² |
| \(x\) | Argument x = φμc_tr²/(4kt) | - |
| \(-Ei(-x)\) | Exponential integral E₁(x) | - |
| \(p(r,t)\) | Pressure at r and t | Pa |
| \(p_i - p\) | Pressure drop | Pa |
| \(p_{log}\) | Pressure by the log approximation | Pa |
| \(t_{pss}\) | Time to pseudo-steady state (circular area) | s |
Method and standards
Constant-rate line-source solution of the diffusivity equation.
Where it is used
- Interference and drawdown test design.
- Pressure profile around a producer.
Common mistakes
- Using it after boundary effects start.
- Using the log approximation at large x.
Assumptions and limits
- Infinite-acting, homogeneous reservoir; slightly compressible fluid; no skin.
Questions and answers
When does the line-source solution apply?
While the reservoir is infinite acting, before the pressure disturbance reaches a boundary, and outside a few wellbore radii unless the wellbore radius is used for p_wf.
Why is most of the drop near the well?
The pressure varies with ln r: the first few feet carry as much drop as the next thousand.
What do the defaults represent?
An illustrative case: Oil well 400 STB/d, 0.3 ft wellbore, after 5 h. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, eqs. 6-78 to 6-82 and Example 6-9; ch. 13 (stabilisation time), Abramowitz and Stegun, Handbook of Mathematical Functions, 5.1 (E₁ by series and continued fraction)