Worked example
Example: Illustrative: 2500 m3/d, T 600 m2/d, S 0.0002, r 50 m, 2 days. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pumping rate | 104.17 m³/h |
| Transmissivity | 600.00 m²/d |
| Storativity (storage coefficient) | 2.0000e-04 - |
| Distance from the well | 50.000 m |
| Time since pumping started | 48.000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Well function argument r²S/(4Tt) | 1.0417e-04 |
| Theis well function | 8.5924 |
| Drawdown (Theis) | 2.8490 m |
| Drawdown (Cooper–Jacob) | 2.8490 m |
| Cooper–Jacob drawdown per log cycle of time | 0.76347 m |
Open this example in the calculator and change any input.
Formula
\(s = \frac{Q}{4\pi T}W(u), \quad W(u) = \int_u^\infty \frac{e^{-x}}{x}dx = E_1(u), \quad u = \frac{r^2S}{4Tt}\)
\(s_{CJ} = \frac{Q}{4\pi T}\left(-0.5772 - \ln u\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Pumping rate | m³/s |
| \(T\) | Transmissivity | m²/s |
| \(S\) | Storativity (storage coefficient) | - |
| \(r\) | Distance from the well | m |
| \(t\) | Time since pumping started | s |
| \(u\) | Well function argument r²S/(4Tt) | - |
| \(W(u)\) | Theis well function | - |
| \(s\) | Drawdown (Theis) | m |
| \(s_{CJ}\) | Drawdown (Cooper–Jacob) | m |
| \(\Delta s\) | Cooper–Jacob drawdown per log cycle of time | m |
Method and standards
Non-equilibrium radial flow to a well.
Where it is used
- Pumping test interpretation and well field design.
- Dewatering of excavations, interference between wells.
Common mistakes
- Mixing units of days and seconds in T and t.
- Using Cooper–Jacob at early times.
Assumptions and limits
- Confined aquifer, Theis assumptions.
References
- Theis non-equilibrium equation with the exponential integral; Cooper–Jacob approximation
Questions and answers
When does Cooper–Jacob work?
When u is small (below about 0.01–0.05), at long times or close to the well; the drawdown then plots as a straight line against log time.
How is a pumping test analysed?
Match the observed drawdown curve to W(u) or fit the Cooper–Jacob straight line; its slope per log cycle gives T = 2.3Q/(4πΔs).
What do the defaults represent?
An illustrative well pumping 2,500 m³/day from an aquifer with T = 600 m²/day and S = 0.0002, observed 50 m away after 2 days.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Todd and Mays, Groundwater Hydrology, 3rd ed. (Wiley, 2005), sec. 4.6, Chow, Maidment and Mays, Applied Hydrology (McGraw-Hill, 1988), ch. 4