FireCADCalc

Specific Energy and Alternate Depths in a Rectangular Channel

Specific energy at a depth, the alternate depth with the same energy, critical depth and minimum energy, and the Froude numbers in a rectangular channel.

Inputs

Examples: Illustrative: 12 m3/s in a 4 m channel at 0.6 m (supercritical)Subcritical: 5 m3/s, 3 m wide, 1.5 m deepBelow a sluice: 2 m3/s, 1 m wide, 0.25 m

Accepted: 0.0001 to 100,000 m³/s
Accepted: 0.05 to 1,000 m
Accepted: 0.001 to 100 m

Results

Rectangular channel, uniform velocity: subcritical and supercritical alternate depths share the same specific energy; at critical depth the energy is a minimum.

Discharge per unit width2.0000m³/(s·m)
Specific energy y + q²/(2gy²)3.5131m
Critical depth0.74162m
Minimum specific energy 1.5 y_c1.1124m
Alternate depth with the same energy3.4964m
Froude number at y₁5.1093
Froude number at y₂0.097687

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 12 m3/s in a 4 m channel at 0.6 m (supercritical). The inputs, in the units selected above:

InputValue
Discharge12.000 m³/s
Channel width4.0000 m
Known depth0.60000 m

Applying the formula below gives:

ResultValue
Discharge per unit width3.0000 m³/(s·m)
Specific energy y + q²/(2gy²)1.8746 m
Critical depth0.97179 m
Minimum specific energy 1.5 y_c1.4577 m
Alternate depth with the same energy1.7194 m
Froude number at y₁2.0613
Froude number at y₂0.42490

Open this example in the calculator and change any input.

Formula

\(E = y + \frac{q^2}{2gy^2}, \quad y_c = \left(\frac{q^2}{g}\right)^{1/3}, \quad E_{min} = \frac{3}{2}y_c, \quad Fr = \frac{q}{y\sqrt{gy}}\)

Variables

Symbol Meaning SI unit
\(Q\) Discharge m³/s
\(b\) Channel width m
\(y_1\) Known depth m
\(q\) Discharge per unit width m³/(s·m)
\(E\) Specific energy y + q²/(2gy²) m
\(y_c\) Critical depth m
\(E_{min}\) Minimum specific energy 1.5 y_c m
\(y_2\) Alternate depth with the same energy m
\(Fr_1\) Froude number at y₁ -
\(Fr_2\) Froude number at y₂ -

Method and standards

Specific energy concept.

Where it is used

  • Flow under gates, over steps and through contractions.
  • Channel transitions and flumes.

Common mistakes

  • Confusing alternate depths with sequent depths.
  • Applying it to non-rectangular sections without the area terms.

Assumptions and limits

  • Rectangular channel, hydrostatic pressure, uniform velocity.

References

  • Specific energy and alternate depths

Questions and answers

What are alternate depths?

For a given discharge and energy there are two possible depths: a deep slow subcritical one and a shallow fast supercritical one.

Is the alternate depth the same as the sequent (jump) depth?

No: alternate depths share energy; sequent depths share momentum. A hydraulic jump loses energy, so its downstream depth is less than the alternate depth.

What do the defaults represent?

An illustrative 4 m wide channel carrying 12 m³/s at a shallow 0.6 m depth.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chow, Open-Channel Hydraulics (McGraw-Hill, 1959), ch. 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.