Worked example
Example: Illustrative: K 10 m/d, river 12 m, drain 6 m, 200 m apart, no recharge. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Hydraulic conductivity | 10.000 m/d |
| Upstream saturated thickness | 12.000 m |
| Downstream saturated thickness | 6.0000 m |
| Flow length between the boundaries | 200.00 m |
| Distance from the upstream boundary for the water table | 100.00 m |
| Recharge rate (0 if none) | 0 mm/d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Seepage at the upstream boundary per metre width | 2.7000 m³/(d·m) |
| Seepage at x per metre width | 2.7000 m³/(d·m) |
| Water table height at x | 9.4868 m |
| Water divide distance (with recharge; 0 if none) | 0 m |
Open this example in the calculator and change any input.
Formula
\(q = \frac{K(h_1^2 - h_2^2)}{2L} - W\left(\frac{L}{2} - x\right), \quad h^2(x) = h_1^2 - \frac{(h_1^2 - h_2^2)x}{L} + \frac{W}{K}(L - x)x\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(K\) | Hydraulic conductivity | m/s |
| \(h_1\) | Upstream saturated thickness | m |
| \(h_2\) | Downstream saturated thickness | m |
| \(L\) | Flow length between the boundaries | m |
| \(x\) | Distance from the upstream boundary for the water table | m |
| \(W\) | Recharge rate (0 if none) | m/s |
| \(q\) | Seepage at the upstream boundary per metre width | m³/(s·m) |
| \(q(x)\) | Seepage at x per metre width | m³/(s·m) |
| \(h(x)\) | Water table height at x | m |
| \(d\) | Water divide distance (with recharge; 0 if none) | m |
Method and standards
Dupuit–Forchheimer unconfined flow.
Where it is used
- Seepage between a river and a drain or canal.
- Dewatering trenches and earth embankments (first estimate).
Common mistakes
- Using it for steep water tables close to a seepage face.
- Mixing permeability in m/s with recharge in mm/day.
Assumptions and limits
- Homogeneous unconfined aquifer on a horizontal impermeable base.
References
- Dupuit–Forchheimer unconfined flow with uniform recharge
Questions and answers
Why is the water table a parabola?
With the flow taken as horizontal, Darcy's law and continuity give d(h²)/dx constant, so h² varies linearly with distance.
What does the water divide mean?
With recharge, groundwater flows both ways from a high point; the divide is where the flow is zero.
What do the defaults represent?
An illustrative sandy aquifer (K 10 m/day) between a river 12 m deep and a drain 6 m deep, 200 m apart, without recharge.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Todd and Mays, Groundwater Hydrology, 3rd ed. (Wiley, 2005), sec. 3.10