FireCADCalc

Dupuit Unconfined Seepage between Two Water Bodies

Seepage per metre width through an unconfined aquifer or embankment between two water levels, with the water table height along the flow, by the Dupuit equation.

Inputs

Examples: Illustrative: K 10 m/d, river 12 m, drain 6 m, 200 m apart, no rechargeWith recharge 2 mm/d between two canals 10 and 9 m, 1000 m apartEmbankment core: K 0.05 m/d, 8 m to 0.5 m over 30 m

Accepted: 8.64E-6 to 8,640 m/d
Accepted: 0.01 to 1,000 m
Accepted: 0 to 1,000 m
Accepted: 0.1 to 100,000 m
Accepted: 0 to 100,000 m
Accepted: 0 to 86.4 mm/d

Results

Dupuit assumptions: horizontal flow, hydraulic gradient equal to the water-table slope, uniform conductivity on an impermeable base. The parabola underestimates the seepage face at the outflow but the discharge is exact for these boundaries.

Seepage at the upstream boundary per metre width0.053125m³/(d·m)
Seepage at x per metre width0.053125m³/(d·m)
Water table height at x4.6368m
Water divide distance (with recharge; 0 if none)0m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: K 10 m/d, river 12 m, drain 6 m, 200 m apart, no recharge. The inputs, in the units selected above:

InputValue
Hydraulic conductivity10.000 m/d
Upstream saturated thickness12.000 m
Downstream saturated thickness6.0000 m
Flow length between the boundaries200.00 m
Distance from the upstream boundary for the water table100.00 m
Recharge rate (0 if none)0 mm/d

Applying the formula below gives:

ResultValue
Seepage at the upstream boundary per metre width2.7000 m³/(d·m)
Seepage at x per metre width2.7000 m³/(d·m)
Water table height at x9.4868 m
Water divide distance (with recharge; 0 if none)0 m

Open this example in the calculator and change any input.

Formula

\(q = \frac{K(h_1^2 - h_2^2)}{2L} - W\left(\frac{L}{2} - x\right), \quad h^2(x) = h_1^2 - \frac{(h_1^2 - h_2^2)x}{L} + \frac{W}{K}(L - x)x\)

Variables

Symbol Meaning SI unit
\(K\) Hydraulic conductivity m/s
\(h_1\) Upstream saturated thickness m
\(h_2\) Downstream saturated thickness m
\(L\) Flow length between the boundaries m
\(x\) Distance from the upstream boundary for the water table m
\(W\) Recharge rate (0 if none) m/s
\(q\) Seepage at the upstream boundary per metre width m³/(s·m)
\(q(x)\) Seepage at x per metre width m³/(s·m)
\(h(x)\) Water table height at x m
\(d\) Water divide distance (with recharge; 0 if none) m

Method and standards

Dupuit–Forchheimer unconfined flow.

Where it is used

  • Seepage between a river and a drain or canal.
  • Dewatering trenches and earth embankments (first estimate).

Common mistakes

  • Using it for steep water tables close to a seepage face.
  • Mixing permeability in m/s with recharge in mm/day.

Assumptions and limits

  • Homogeneous unconfined aquifer on a horizontal impermeable base.

References

  • Dupuit–Forchheimer unconfined flow with uniform recharge

Questions and answers

Why is the water table a parabola?

With the flow taken as horizontal, Darcy's law and continuity give d(h²)/dx constant, so h² varies linearly with distance.

What does the water divide mean?

With recharge, groundwater flows both ways from a high point; the divide is where the flow is zero.

What do the defaults represent?

An illustrative sandy aquifer (K 10 m/day) between a river 12 m deep and a drain 6 m deep, 200 m apart, without recharge.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todd and Mays, Groundwater Hydrology, 3rd ed. (Wiley, 2005), sec. 3.10

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.