Worked example
Example: Weir on silty sand. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Coefficient of permeability | 5.0000e-06 m/s |
| Head difference upstream to downstream | 6.0000 m |
| Number of flow channels | 4.0000 - |
| Number of equipotential drops | 12.000 - |
| Length of the structure | 50.000 m |
| Size of the last square at the exit | 1.2000 m |
| Submerged to water unit weight ratio | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Seepage per metre | 0.86400 m³/(d·m) |
| Total seepage | 43.200 m³/d |
| Exit gradient (H/N_d)/l_e | 0.41667 |
| Safety against piping i_c/i_e | 2.4000 |
Open this example in the calculator and change any input.
Formula
\(q = k H \frac{N_f}{N_d}, \quad i_e = \frac{H/N_d}{l_e}, \quad FS = \frac{\gamma'/\gamma_w}{i_e}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k\) | Coefficient of permeability | m/s |
| \(H\) | Head difference upstream to downstream | m |
| \(N_f\) | Number of flow channels | - |
| \(N_d\) | Number of equipotential drops | - |
| \(B\) | Length of the structure | m |
| \(l_e\) | Size of the last square at the exit | m |
| \(\gamma'/\gamma_w\) | Submerged to water unit weight ratio | - |
| \(q\) | Seepage per metre | m³/(s·m) |
| \(Q\) | Total seepage | m³/s |
| \(i_e\) | Exit gradient (H/N_d)/l_e | - |
| \(FS\) | Safety against piping i_c/i_e | - |
Method and standards
Flow net theory.
Where it is used
- Seepage under weirs, cofferdams and pond bunds.
- Piping checks.
Common mistakes
- Counting lines instead of channels.
- Ignoring anisotropy.
Assumptions and limits
- Isotropic, steady flow. With zero head the piping safety factor is not shown.
References
- Flow net seepage q = k H N_f/N_d; critical gradient γ'/γ_w (Das; Craig)
Questions and answers
k 5e-6, 6 m head, 4 channels, 12 drops?
0.86 m³/day per metre; exit gradient 0.42.
Why squares?
A flow net of curvilinear squares makes the formula exact for isotropic soil.
Anisotropic soil?
Use √(kₓk_z) on a transformed section.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.