FireCADCalc

Coulomb Active Earth Pressure with Wall Friction

Coulomb active earth pressure coefficient and thrust on a retaining wall with wall friction, a sloping back and a sloping backfill, for a cohesionless soil.

Inputs

Examples: Vertical wall, level fillSloping fill 15 degreesWall back leaning 10 degrees

Results

The thrust acts at H/3 above the base, inclined at δ to the normal of the wall back.

Active coefficient0.27554
Active thrust per metre ½K_aγH²61.996kN/m
Horizontal component58.257kN/m
Vertical component21.204kN/m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Vertical wall, level fill. The inputs, in the units selected above:

InputValue
Soil friction angle32.000 °
Wall friction angle20.000 °
Back of wall from vertical (positive when it slopes away from the fill)0 °
Backfill slope0 °
Unit weight of the fill18.000 kN/m³
Wall height5.0000 m

Applying the formula below gives:

ResultValue
Active coefficient0.27554
Active thrust per metre ½K_aγH²61.996 kN/m
Horizontal component58.257 kN/m
Vertical component21.204 kN/m

Open this example in the calculator and change any input.

Formula

\(K_a = \frac{\cos^2(\phi - \theta)}{\cos^2\theta\cos(\delta + \theta)\left[1 + \sqrt{\frac{\sin(\phi + \delta)\sin(\phi - \beta)}{\cos(\delta + \theta)\cos(\theta - \beta)}}\right]^2}\)

Variables

Symbol Meaning SI unit
\(\phi\) Soil friction angle rad
\(\delta\) Wall friction angle rad
\(\theta\) Back of wall from vertical (positive when it slopes away from the fill) rad
\(\beta\) Backfill slope rad
\(\gamma\) Unit weight of the fill N/m³
\(H\) Wall height m
\(K_a\) Active coefficient -
\(P_a\) Active thrust per metre ½K_aγH² N/m
\(P_h\) Horizontal component N/m
\(P_v\) Vertical component N/m

Method and standards

Coulomb wedge theory.

Where it is used

  • Retaining walls, bunker walls and abutments.
  • Coal and ash yard walls.

Common mistakes

  • Sign of θ.
  • Cohesive soils.

Assumptions and limits

  • Dry cohesionless backfill, planar wedge; δ not above φ.
  • Sign of θ: positive when the back of the wall slopes away from the fill going up, so the fill overhangs the wall back; this raises K_a (θ = 10°, φ = 30°, δ = β = 0 gives 0.407 against 0.333 for a vertical back). Negative θ (back leaning into the fill) lowers it.

References

  • Coulomb's active earth pressure coefficient (Das, Principles of Foundation Engineering)

Questions and answers

φ 32°, δ 20°, vertical wall, level fill?

K_a about 0.28; thrust on a 5 m wall about 62 kN per metre.

How does it differ from Rankine?

Coulomb includes wall friction, which lowers K_a and tilts the thrust.

Which δ?

Commonly ⅔φ for concrete on soil; your design basis decides.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.