FireCADCalc

Retaining Wall Stability: Overturning, Sliding and Base Pressure

Factors of safety against overturning and sliding of a gravity or cantilever retaining wall, and the base pressures, from its weights, lever arms and earth thrust.

Inputs

Examples: Cantilever wall, middle thirdResultant outside middle third

Results

Against overturning M_R/M_O4.0444
Against sliding (μW + P_p)/P_h1.7333
Eccentricity of the resultant0.16923m
Maximum base pressure95.837kPa
Minimum base pressure52.735kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Cantilever wall, middle third. The inputs, in the units selected above:

InputValue
Total vertical load (wall and soil on the heel)260.00 kN/m
Lever arm of W from the toe2.1000 m
Horizontal earth thrust75.000 kN/m
Height of the thrust above the base1.8000 m
Base width3.5000 m
Base friction coefficient0.50000 -
Passive resistance counted0 kN/m

Applying the formula below gives:

ResultValue
Against overturning M_R/M_O4.0444
Against sliding (μW + P_p)/P_h1.7333
Eccentricity of the resultant0.16923 m
Maximum base pressure95.837 kPa
Minimum base pressure52.735 kPa

Open this example in the calculator and change any input.

Formula

\(FS_o = \frac{W x_W}{P_h y_h}, \quad FS_s = \frac{\mu W + P_p}{P_h}, \quad q = \frac{W}{B}\left(1 \pm \frac{6e}{B}\right)\ (|e| \le B/6)\)

\(x = \frac{W x_W - P_h y_h}{W}, \quad e = \frac{B}{2} - x, \quad q_{max} = \frac{2W}{3x'},\ q_{min} = 0\ \ (|e| > B/6,\ x' = \min(x, B - x))\)

Variables

Symbol Meaning SI unit
\(W\) Total vertical load (wall and soil on the heel) N/m
\(x_W\) Lever arm of W from the toe m
\(P_h\) Horizontal earth thrust N/m
\(y_h\) Height of the thrust above the base m
\(B\) Base width m
\(\mu\) Base friction coefficient -
\(P_p\) Passive resistance counted N/m
\(FS_o\) Against overturning M_R/M_O -
\(FS_s\) Against sliding (μW + P_p)/P_h -
\(e\) Eccentricity of the resultant m
\(x\) Distance of the resultant from the toe m
\(x'\) Distance of the resultant from the nearer edge of the base m
\(q_{max}\) Maximum base pressure Pa
\(q_{min}\) Minimum base pressure Pa

Method and standards

Statics of a rigid wall.

Where it is used

  • Retaining walls, bund walls and pits.
  • Coal and ash yard walls.

Common mistakes

  • Counting full passive resistance.
  • Leaving out the soil on the heel.

Assumptions and limits

  • Rigid wall per metre run.
  • With no overturning moment or no horizontal thrust the matching factor of safety is not applicable and is not shown.
  • Outside the middle third the base pressure is a triangle over 3x', and the minimum pressure is zero (part of the base lifts).

References

  • Rigid-body stability of retaining walls; trapezoidal base pressure (Das, Principles of Foundation Engineering)

Questions and answers

W 260 kN/m at 2.1 m, thrust 75 kN/m at 1.8 m, 3.5 m base?

Overturning FS 4.04, sliding FS 1.73.

What factors are required?

Your design code's; often 2 for overturning and 1.5 for sliding.

Why keep the resultant in the middle third?

So the whole base stays in compression.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.