Worked example
Example: Cantilever wall, middle third. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Total vertical load (wall and soil on the heel) | 260.00 kN/m |
| Lever arm of W from the toe | 2.1000 m |
| Horizontal earth thrust | 75.000 kN/m |
| Height of the thrust above the base | 1.8000 m |
| Base width | 3.5000 m |
| Base friction coefficient | 0.50000 - |
| Passive resistance counted | 0 kN/m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Against overturning M_R/M_O | 4.0444 |
| Against sliding (μW + P_p)/P_h | 1.7333 |
| Eccentricity of the resultant | 0.16923 m |
| Maximum base pressure | 95.837 kPa |
| Minimum base pressure | 52.735 kPa |
Open this example in the calculator and change any input.
Formula
\(FS_o = \frac{W x_W}{P_h y_h}, \quad FS_s = \frac{\mu W + P_p}{P_h}, \quad q = \frac{W}{B}\left(1 \pm \frac{6e}{B}\right)\ (|e| \le B/6)\)
\(x = \frac{W x_W - P_h y_h}{W}, \quad e = \frac{B}{2} - x, \quad q_{max} = \frac{2W}{3x'},\ q_{min} = 0\ \ (|e| > B/6,\ x' = \min(x, B - x))\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Total vertical load (wall and soil on the heel) | N/m |
| \(x_W\) | Lever arm of W from the toe | m |
| \(P_h\) | Horizontal earth thrust | N/m |
| \(y_h\) | Height of the thrust above the base | m |
| \(B\) | Base width | m |
| \(\mu\) | Base friction coefficient | - |
| \(P_p\) | Passive resistance counted | N/m |
| \(FS_o\) | Against overturning M_R/M_O | - |
| \(FS_s\) | Against sliding (μW + P_p)/P_h | - |
| \(e\) | Eccentricity of the resultant | m |
| \(x\) | Distance of the resultant from the toe | m |
| \(x'\) | Distance of the resultant from the nearer edge of the base | m |
| \(q_{max}\) | Maximum base pressure | Pa |
| \(q_{min}\) | Minimum base pressure | Pa |
Method and standards
Statics of a rigid wall.
Where it is used
- Retaining walls, bund walls and pits.
- Coal and ash yard walls.
Common mistakes
- Counting full passive resistance.
- Leaving out the soil on the heel.
Assumptions and limits
- Rigid wall per metre run.
- With no overturning moment or no horizontal thrust the matching factor of safety is not applicable and is not shown.
- Outside the middle third the base pressure is a triangle over 3x', and the minimum pressure is zero (part of the base lifts).
References
- Rigid-body stability of retaining walls; trapezoidal base pressure (Das, Principles of Foundation Engineering)
Questions and answers
W 260 kN/m at 2.1 m, thrust 75 kN/m at 1.8 m, 3.5 m base?
Overturning FS 4.04, sliding FS 1.73.
What factors are required?
Your design code's; often 2 for overturning and 1.5 for sliding.
Why keep the resultant in the middle third?
So the whole base stays in compression.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.