Worked example
Example: Square 2 m footing, 1.5 m deep, sand 30°. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Footing | Square |
| Width (or diameter) | 2.0000 m |
| Length (rectangular footing) | 3.0000 m |
| Depth of the base below ground | 1.5000 m |
| Bulk density of the soil | 1,800.0 kg/m³ |
| Angle of internal friction | 30.000 ° |
| Cohesion | 0 kPa |
| Factor of safety | 3.0000 - |
| Depth of the water table below ground | 100.00 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bearing capacity factor N_c | 30.140 |
| Bearing capacity factor N_q | 18.401 |
| Bearing capacity factor N_γ | 22.402 |
| Effective overburden pressure at the base | 26.478 kPa |
| Ultimate bearing capacity | 1,005.8 kPa |
| Safe bearing capacity (gross, q_u / F_s) | 335.26 kPa |
| Net safe bearing capacity (q_u − q)/F_s | 326.44 kPa |
Open this example in the calculator and change any input.
Formula
\(q_u = c N_c F_{cs} + q N_q F_{qs} + \tfrac12 \gamma B N_\gamma F_{\gamma s}\)
Water table at depth \(D_w\), with \(\gamma = \rho g\) and \(\gamma' = (\rho - \rho_w) g\) (Das):
\(D_w \le D_f:\ q = \gamma D_w + \gamma'(D_f - D_w),\ \gamma \to \gamma'; \quad D_f < D_w < D_f + B:\ q = \gamma D_f,\ \gamma \to \gamma' + \frac{D_w - D_f}{B}(\gamma - \gamma'); \quad D_w \ge D_f + B:\ \text{no effect}\)
\(N_q = e^{\pi \tan\varphi} \tan^2\left(45° + \frac{\varphi}{2}\right), \quad N_c = (N_q - 1)\cot\varphi, \quad N_\gamma = 2 (N_q + 1) \tan\varphi\)
\(F_{cs} = 1 + \frac{B}{L}\frac{N_q}{N_c}, \quad F_{qs} = 1 + \frac{B}{L}\tan\varphi, \quad F_{\gamma s} = 1 - 0.4\frac{B}{L}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{shape}\) | Footing | - |
| \(B\) | Width (or diameter) | m |
| \(L\) | Length (rectangular footing) | m |
| \(D_f\) | Depth of the base below ground | m |
| \(\rho\) | Bulk density of the soil | kg/m³ |
| \(\varphi\) | Angle of internal friction | rad |
| \(c\) | Cohesion | Pa |
| \(F_s\) | Factor of safety | - |
| \(D_w\) | Depth of the water table below ground | m |
| \(\gamma, \gamma'\) | Bulk and submerged unit weight | N/m³ |
| \(\rho_w\) | Density of water, 1000 | kg/m³ |
| \(N_c\) | Bearing capacity factor N_c | - |
| \(N_q\) | Bearing capacity factor N_q | - |
| \(N_\gamma\) | Bearing capacity factor N_γ | - |
| \(q\) | Effective overburden pressure at the base | Pa |
| \(q_u\) | Ultimate bearing capacity | Pa |
| \(q_a\) | Safe bearing capacity (gross, q_u / F_s) | Pa |
| \(q_{ns}\) | Net safe bearing capacity (q_u − q)/F_s | Pa |
| \(g\) | Standard gravity | m/s² |
| \(F_{cs}, F_{qs}, F_{\gamma s}\) | Shape factors | - |
Method and standards
The general bearing capacity equation with Prandtl–Reissner N_c and N_q, Vesić's N_γ and De Beer's shape factors as given by Das; depth and inclination factors are left out, which is conservative.
Where it is used
- Sizing footings for equipment, pipe racks and small buildings.
- Checking a soil report's safe bearing capacity.
- Comparing footing widths and depths.
Common mistakes
- Using total instead of effective unit weight below the water table.
- Treating safe bearing capacity as allowable without a settlement check.
- Mixing factors from different methods.
Assumptions and limits
- General shear failure; vertical, central load; level ground. The factors are Prandtl–Reissner N_c and N_q, Vesić N_γ and De Beer shape factors in Terzaghi's general form, not Terzaghi's own factors (1.3 c N_c, 0.4 γ B N_γ).
- No local or punching shear reduction is applied: for loose sand or soft clay, where local shear governs, the result is unconservative; a common practice is to repeat with c and tan φ reduced to two-thirds (Terzaghi's local shear).
- A water table within B below the base reduces the overburden and N_γ terms (Das's three cases); the soil below it is taken as saturated at the bulk density entered.
References
- Terzaghi (1943) general form; Prandtl–Reissner N_c
- N_q; Vesić (1973) N_γ; De Beer (1970) shape factors (Das, Principles of Foundation Engineering)
Questions and answers
What can a 2 m square footing 1.5 m deep in 30° sand carry?
N_q 18.4, N_γ 22.4: ultimate 1 006 kPa, safe 335 kPa with a factor of 3.
What about clay with no friction?
N_c = π + 2 = 5.14: a 1.2 m strip in 50 kPa clay at 1 m depth has 275 kPa ultimate, 92 kPa safe.
Is this the allowable bearing pressure?
It is the safe value against shear failure; settlement often governs and needs its own check.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.