Worked example
Example: 600 mm, 15 m bored pile in clay, c_u 60 kPa. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Soil | Clay (α method) |
| Pile diameter | 600.00 mm |
| Embedded length | 15.000 m |
| Undrained shear strength (clay) | 60.000 kPa |
| Adhesion factor (clay) | 0.50000 - |
| Effective unit weight (sand) | 9.0000 kN/m³ |
| Shaft friction factor (sand) | 0.30000 - |
| Base bearing factor (sand) | 40.000 - |
| Factor of safety | 2.5000 - |
| Critical depth in diameters (sand) | 15.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Shaft capacity | 848.23 kN |
| Base capacity | 152.68 kN |
| Ultimate capacity | 1,000.9 kN |
| Allowable load | 400.36 kN |
Open this example in the calculator and change any input.
Formula
\(Q_s = \alpha c_uA_s,\ Q_b = 9c_uA_b\ \text{(clay)}; \quad Q_s = \beta\bar\sigma'_vA_s,\ Q_b = N_q\sigma'_{v,tip}A_b\ \text{(sand)}\)
\(\sigma'_v(z) = \gamma' \min(z, z_c), \quad z_c = (z_c/D)\,D\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{soil}\) | Soil | - |
| \(D\) | Pile diameter | m |
| \(L\) | Embedded length | m |
| \(c_u\) | Undrained shear strength (clay) | Pa |
| \(\alpha\) | Adhesion factor (clay) | - |
| \(\gamma'\) | Effective unit weight (sand) | N/m³ |
| \(\beta\) | Shaft friction factor (sand) | - |
| \(N_q\) | Base bearing factor (sand) | - |
| \(FS\) | Factor of safety | - |
| \(z_c/D\) | Critical depth in diameters (sand) | - |
| \(Q_s\) | Shaft capacity | N |
| \(Q_b\) | Base capacity | N |
| \(Q_u\) | Ultimate capacity | N |
| \(Q_a\) | Allowable load | N |
Method and standards
Static capacity.
Where it is used
- Pile foundations for boilers, chimneys and tanks.
- Preliminary pile length.
Common mistakes
- Ignoring negative skin friction in fill.
- Using the β method without limiting stresses for long piles.
Assumptions and limits
- Single layer; vertical load; water table at the ground surface (γ′ is the submerged unit weight).
- The pile's own weight is not subtracted from Q_a; subtract it (less the displaced soil) for a net allowable load.
- Sand: the effective vertical stress for shaft friction and end bearing stops rising below the critical depth (10–20 diameters is the usual range; 15 is the default).
References
- α and β methods for pile capacity (Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011), ch. 11)
Questions and answers
Why is shaft friction usually larger?
A long pile has much more shaft area than base area, and base resistance needs large settlement to mobilise.
What α should I use?
About 1 for soft clay, falling to 0.3–0.5 for stiff clay; check local correlations.
What do the defaults represent?
A 600 mm, 15 m bored pile in clay with c_u = 60 kPa.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.