FireCADCalc

Atterberg Limits: Plasticity, Liquidity and Consistency Indices

Plasticity index, liquidity index, consistency index and activity of a fine soil from its liquid limit, plastic limit, natural water content and clay fraction.

Inputs

Examples: Clay of medium plasticitySilt below the A-lineSoft clay above its liquid limit

Results

Above the A-line on the plasticity chart: clay.

Plasticity index w_L − w_P26.000%
Liquidity index (w − w_P)/I_P0.30769
Consistency index (w_L − w)/I_P0.69231
Activity I_P/clay fraction (both in %)0.74286
A-line value 0.73(w_L − 20 %)20.440%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Clay of medium plasticity. The inputs, in the units selected above:

InputValue
Liquid limit48.000 %
Plastic limit22.000 %
Natural water content30.000 %
Clay fraction (finer than 2 µm)35.000 %

Applying the formula below gives:

ResultValue
Plasticity index w_L − w_P26.000 %
Liquidity index (w − w_P)/I_P0.30769
Consistency index (w_L − w)/I_P0.69231
Activity I_P/clay fraction (both in %)0.74286
A-line value 0.73(w_L − 20 %)20.440 %

Open this example in the calculator and change any input.

Formula

\(I_P = w_L - w_P, \quad I_L = \frac{w - w_P}{I_P}, \quad I_C = \frac{w_L - w}{I_P}, \quad A = \frac{I_P}{c}\)

Variables

Symbol Meaning SI unit
\(w_L\) Liquid limit -
\(w_P\) Plastic limit -
\(w\) Natural water content -
\(c\) Clay fraction (finer than 2 µm) -
\(I_P\) Plasticity index w_L − w_P -
\(I_L\) Liquidity index (w − w_P)/I_P -
\(I_C\) Consistency index (w_L − w)/I_P -
\(A\) Activity I_P/clay fraction (both in %) -
\(I_{P,A}\) A-line value 0.73(w_L − 20 %) -

Method and standards

Definitions.

Where it is used

  • Soil classification.
  • Foundation and earthwork suitability.

Common mistakes

  • Mixing percent and fraction.
  • Non-plastic soils.

Assumptions and limits

  • Fine soils. The note is a simple A-line check; ASTM D2487 also has the CL-ML band (PI 4–7) and needs PI of at least 7 above the A-line for CL, so low-PI soils are flagged rather than called clay.

References

  • Atterberg limit indices; Casagrande A-line I_P = 0.73(w_L − 20) (ASTM D2487)

Questions and answers

LL 48 %, PL 22 %, w 30 %?

PI 26 %, liquidity index 0.31, consistency index 0.69; above the A-line, a clay.

What does liquidity index tell?

Near 0 the soil is stiff, near 1 it is close to liquid.

Activity?

High activity (> 1.25) means swelling clay minerals.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators