Worked example
Example: Illustrative 1.5 m crest, 0.3 m head. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crest length (bottom width) | 1.5000 m |
| Head over the crest | 0.30000 m |
| Broad-crested weir coefficient | 0.90000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cipolletti weir | 0.45844 m³/s |
| Broad-crested weir | 0.37813 m³/s |
| Critical depth on the broad crest | 200.00 mm |
Open this example in the calculator and change any input.
Formula
\(Q_C = 1.86LH^{3/2}, \quad Q_B = C_dL\sqrt g\left(\frac{2H}{3}\right)^{3/2} = 1.705C_dLH^{3/2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Crest length (bottom width) | m |
| \(H\) | Head over the crest | m |
| \(C_d\) | Broad-crested weir coefficient | - |
| \(Q_C\) | Cipolletti weir | m³/s |
| \(Q_B\) | Broad-crested weir | m³/s |
| \(y_c\) | Critical depth on the broad crest | m |
Method and standards
Weirs.
Where it is used
- Irrigation and effluent flow measurement.
- Civil engineering examinations.
Common mistakes
- Measuring head too close to the crest.
- Using free-flow formulas when submerged.
Assumptions and limits
- Negligible approach velocity; free flow.
References
- Classical engineering hydrology relations: weir formulas
Questions and answers
What flows over a 1.5 m Cipolletti weir at 0.3 m head?
About 0.46 m³/s; a broad-crested weir of the same length with C_d 0.9 passes about 0.38 m³/s.
Why is the Cipolletti weir trapezoidal?
The 1:4 side slopes compensate for end contractions, so Q stays proportional to crest length.
What do the defaults represent?
An illustrative 1.5 m crest with 0.3 m head and a broad-crest coefficient of 0.9.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.