FireCADCalc

Cipolletti and Broad-Crested Weir Discharge

Discharge over a Cipolletti (trapezoidal, 1:4 sides) weir and over a broad-crested weir from crest length and head, with the critical depth on the broad crest.

Inputs

Examples: Illustrative 1.5 m crest, 0.3 m headField channel weirLarge broad crest

Accepted: 0.05 to 100 m
Accepted: 0.01 to 10 m
Accepted: 0.5 to 1.1

Results

A Cipolletti weir has side slopes of 1 horizontal to 4 vertical, chosen so the added side area offsets end contractions; its discharge is Q = 1.86LH^1.5 (SI), proportional to crest length. On a broad crest the flow passes through critical depth 2H/3, giving Q = C_d·L·√g·(2H/3)^1.5 = 1.705C_d·L·H^1.5; C_d is 0.85–1.0 depending on the upstream rounding and crest length. Neglect of approach velocity is assumed; keep the weir free-flowing (tailwater below the crest).

Cipolletti weir0.038659m³/s
Broad-crested weir0.030115m³/s
Critical depth on the broad crest80.000mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1.5 m crest, 0.3 m head. The inputs, in the units selected above:

InputValue
Crest length (bottom width)1.5000 m
Head over the crest0.30000 m
Broad-crested weir coefficient0.90000 -

Applying the formula below gives:

ResultValue
Cipolletti weir0.45844 m³/s
Broad-crested weir0.37813 m³/s
Critical depth on the broad crest200.00 mm

Open this example in the calculator and change any input.

Formula

\(Q_C = 1.86LH^{3/2}, \quad Q_B = C_dL\sqrt g\left(\frac{2H}{3}\right)^{3/2} = 1.705C_dLH^{3/2}\)

Variables

Symbol Meaning SI unit
\(L\) Crest length (bottom width) m
\(H\) Head over the crest m
\(C_d\) Broad-crested weir coefficient -
\(Q_C\) Cipolletti weir m³/s
\(Q_B\) Broad-crested weir m³/s
\(y_c\) Critical depth on the broad crest m

Method and standards

Weirs.

Where it is used

  • Irrigation and effluent flow measurement.
  • Civil engineering examinations.

Common mistakes

  • Measuring head too close to the crest.
  • Using free-flow formulas when submerged.

Assumptions and limits

  • Negligible approach velocity; free flow.

References

  • Classical engineering hydrology relations: weir formulas

Questions and answers

What flows over a 1.5 m Cipolletti weir at 0.3 m head?

About 0.46 m³/s; a broad-crested weir of the same length with C_d 0.9 passes about 0.38 m³/s.

Why is the Cipolletti weir trapezoidal?

The 1:4 side slopes compensate for end contractions, so Q stays proportional to crest length.

What do the defaults represent?

An illustrative 1.5 m crest with 0.3 m head and a broad-crest coefficient of 0.9.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.