FireCADCalc

Wilson Activity Coefficients for a Binary Mixture

Activity coefficients and excess Gibbs energy of a binary liquid by the Wilson equation from user energy parameters and molar volumes, with infinite-dilution values.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Ethanol–water x = 0.3, 80 °CAcetone–methanol style

Results

Activity coefficient of 11.1579
Activity coefficient of 21.1621
γ₁ at infinite dilution1.8332
γ₂ at infinite dilution1.8065
Excess Gibbs energy / RT0.14842

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ethanol–water x = 0.3, 80 °C. The inputs, in the units selected above:

InputValue
Mole fraction of component 130.000 %
Temperature80.000 °C
Wilson energy a₁₂399.00 cal/mol
Wilson energy a₂₁933.00 cal/mol
Molar volume of component 158.680 cm³/mol
Molar volume of component 218.070 cm³/mol

Applying the formula below gives:

ResultValue
Activity coefficient of 11.6884
Activity coefficient of 21.2072
γ₁ at infinite dilution6.6001
γ₂ at infinite dilution2.6571
Excess Gibbs energy / RT0.28895

Open this example in the calculator and change any input.

Formula

\(\ln\gamma_1 = -\ln(x_1 + \Lambda_{12}x_2) + x_2\left(\frac{\Lambda_{12}}{x_1 + \Lambda_{12}x_2} - \frac{\Lambda_{21}}{x_2 + \Lambda_{21}x_1}\right)\)

\(\Lambda_{12} = \frac{V_2}{V_1}e^{-a_{12}/RT}, \quad \ln\gamma_1^\infty = -\ln\Lambda_{12} + 1 - \Lambda_{21}, \quad \frac{G^E}{RT} = -x_1\ln(x_1 + \Lambda_{12}x_2) - x_2\ln(x_2 + \Lambda_{21}x_1)\)

Variables

Symbol Meaning SI unit
\(x_1\) Mole fraction of component 1 -
\(T\) Temperature K
\(a_{12}\) Wilson energy a₁₂ J/mol
\(a_{21}\) Wilson energy a₂₁ J/mol
\(V_1\) Molar volume of component 1 m³/mol
\(V_2\) Molar volume of component 2 m³/mol
\(\gamma_1\) Activity coefficient of 1 -
\(\gamma_2\) Activity coefficient of 2 -
\(\gamma_1^\infty\) γ₁ at infinite dilution -
\(\gamma_2^\infty\) γ₂ at infinite dilution -
\(G^E/RT\) Excess Gibbs energy / RT -
\(R\) Gas constant 8.314 462 618 J/(mol·K)

Method and standards

Wilson local-composition model as given in Perry's sec. 4.

Where it is used

  • VLE for distillation design.
  • Checking literature parameters against data.

Common mistakes

  • Swapping a₁₂ and a₂₁.
  • Mixing cal and J.

Assumptions and limits

  • Miscible liquids only.
  • The default energies are FireCAD's fit to FireCAD ethanol–water x–y–T data, not published parameters; use literature values for other systems.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 4 (thermodynamics: excess Gibbs energy models)
  • Wilson equation

Questions and answers

Can Wilson predict two liquid phases?

No; for partially miscible systems use NRTL.

What units are the energies in?

J/mol here; DECHEMA tables give cal/mol, selectable in the unit list.

What do the defaults represent?

Ethanol (1)–water (2) with energies 399 and 933 cal/mol fitted by FireCAD to FireCAD ethanol–water x–y–T data at 1 atm (the same fit as the ethanol–water VLE pages).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.