Tray Column Diameter from Souders–Brown Flooding

Flooding velocity, net area and diameter of a tray column from the vapour load, densities, flood C-factor with surface-tension correction and design flood fraction.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Perry 14: 25 500 kg/h, C 0.095, σ 25Vacuum column

Results

C_SB comes from a flooding chart (Fair, or the vendor's) at the flow parameter and tray spacing; check downcomer backup separately.

C-factor corrected for surface tension0.099336m/s
Flooding velocity on the net area4.1525m/s
Net area4.4330m²
Tower area5.0375m²
Tower diameter2.5326m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Perry 14: 25 500 kg/h, C 0.095, σ 25. The inputs, in the units selected above:

InputValue
Vapour mass flow25,500 kg/h
Vapour density0.48100 kg/m³
Liquid density841.00 kg/m³
Flood C-factor at σ = 20 mN/m (from the tray chart)0.095000 m/s
Liquid surface tension25.000 mN/m
Design fraction of flood80.000 %
Downcomer share of the tower area12.000 %

Applying the formula below gives:

ResultValue
C-factor corrected for surface tension0.099336 m/s
Flooding velocity on the net area4.1525 m/s
Net area4.4330 m²
Tower area5.0375 m²
Tower diameter2.5326 m

Open this example in the calculator and change any input.

Formula

\(u_{flood} = C_{SB}\left(\frac{\sigma}{20}\right)^{0.2}\sqrt{\frac{\rho_L - \rho_G}{\rho_G}}, \quad A_N = \frac{\dot m_V}{\rho_G f u_{flood}}, \quad A_T = \frac{A_N}{1 - A_D/A_T}\)

Variables

Symbol Meaning SI unit
\(\dot m_V\) Vapour mass flow kg/s
\(\rho_G\) Vapour density kg/m³
\(\rho_L\) Liquid density kg/m³
\(C_{SB}\) Flood C-factor at σ = 20 mN/m (from the tray chart) m/s
\(\sigma\) Liquid surface tension N/m
\(f\) Design fraction of flood -
\(A_D/A_T\) Downcomer share of the tower area -
\(C_{SB,\sigma}\) C-factor corrected for surface tension m/s
\(u_{flood}\) Flooding velocity on the net area m/s
\(A_N\) Net area m²
\(A_T\) Tower area m²
\(D_T\) Tower diameter m

Method and standards

Souders–Brown entrainment flooding as in Perry's sec. 14.

Where it is used

  • Preliminary column sizing.
  • Rating existing columns.

Common mistakes

  • Using C_SB at the wrong tray spacing.
  • Basing velocity on the tower area.

Assumptions and limits

  • Spray-regime entrainment flood; σ in mN/m.
  • The flow parameter and tray spacing are not inputs: read C_SB from the flooding chart for them. Downcomer backup and weeping are not checked.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 14 (equipment for distillation and gas absorption)
  • Eq. (14-80) and the surface-tension correction (σ/20)^0.2 of the worked example

Questions and answers

What is the net area?

Tower area minus one downcomer: the area the vapour uses above the tray.

Why correct for surface tension?

Charts are drawn at 20 mN/m; Perry's applies (σ/20)^0.2.

What flood fraction is usual?

75–85 % for non-foaming services, lower for foaming ones.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.