Worked example
Example: Perry 14: 25 500 kg/h, C 0.095, σ 25. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vapour mass flow | 25,500 kg/h |
| Vapour density | 0.48100 kg/m³ |
| Liquid density | 841.00 kg/m³ |
| Flood C-factor at σ = 20 mN/m (from the tray chart) | 0.095000 m/s |
| Liquid surface tension | 25.000 mN/m |
| Design fraction of flood | 80.000 % |
| Downcomer share of the tower area | 12.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| C-factor corrected for surface tension | 0.099336 m/s |
| Flooding velocity on the net area | 4.1525 m/s |
| Net area | 4.4330 m² |
| Tower area | 5.0375 m² |
| Tower diameter | 2.5326 m |
Open this example in the calculator and change any input.
Formula
\(u_{flood} = C_{SB}\left(\frac{\sigma}{20}\right)^{0.2}\sqrt{\frac{\rho_L - \rho_G}{\rho_G}}, \quad A_N = \frac{\dot m_V}{\rho_G f u_{flood}}, \quad A_T = \frac{A_N}{1 - A_D/A_T}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_V\) | Vapour mass flow | kg/s |
| \(\rho_G\) | Vapour density | kg/m³ |
| \(\rho_L\) | Liquid density | kg/m³ |
| \(C_{SB}\) | Flood C-factor at σ = 20 mN/m (from the tray chart) | m/s |
| \(\sigma\) | Liquid surface tension | N/m |
| \(f\) | Design fraction of flood | - |
| \(A_D/A_T\) | Downcomer share of the tower area | - |
| \(C_{SB,\sigma}\) | C-factor corrected for surface tension | m/s |
| \(u_{flood}\) | Flooding velocity on the net area | m/s |
| \(A_N\) | Net area | m² |
| \(A_T\) | Tower area | m² |
| \(D_T\) | Tower diameter | m |
Method and standards
Souders–Brown entrainment flooding as in Perry's sec. 14.
Where it is used
- Preliminary column sizing.
- Rating existing columns.
Common mistakes
- Using C_SB at the wrong tray spacing.
- Basing velocity on the tower area.
Assumptions and limits
- Spray-regime entrainment flood; σ in mN/m.
- The flow parameter and tray spacing are not inputs: read C_SB from the flooding chart for them. Downcomer backup and weeping are not checked.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 14 (equipment for distillation and gas absorption)
- Eq. (14-80) and the surface-tension correction (σ/20)^0.2 of the worked example
Questions and answers
What is the net area?
Tower area minus one downcomer: the area the vapour uses above the tray.
Why correct for surface tension?
Charts are drawn at 20 mN/m; Perry's applies (σ/20)^0.2.
What flood fraction is usual?
75–85 % for non-foaming services, lower for foaming ones.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.