FireCADCalc

Constant-Pressure Filtration Time (Ruth Equation)

Filtration time for a filtrate volume, and the volume after a time, at constant pressure from the Ruth constants found by a test (t/V against V).

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Test constants, 0.2 m3 and 1 hFine cake

s/m⁶, from a filtration test plotted as t/V vs V.

Results

Constants hold for the same slurry, cake, area and pressure as the test.

Time to collect V1,125.0min
Volume collected in t0.006718m³
Filtration rate at V0.001385m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Test constants, 0.2 m3 and 1 h. The inputs, in the units selected above:

InputValue
Slope of t/V against V2,000,000 -
Intercept of t/V (s/m³)20,000 -
Filtrate volume0.20000 m³
Filtration time60.000 min

Applying the formula below gives:

ResultValue
Time to collect V733.33 min
Volume collected in t0.050828 m³
Filtration rate at V0.008571 m³/h

Open this example in the calculator and change any input.

Formula

\(t = \frac{K_p}{2}V^2 + B V, \quad V = \frac{-B + \sqrt{B^2 + 2K_p t}}{K_p}\)

Variables

Symbol Meaning SI unit
\(K_p\) Slope of t/V against V -
\(B\) Intercept of t/V (s/m³) -
\(V\) Filtrate volume m³
\(t\) Filtration time s
\(t(V)\) Time to collect V s
\(V(t)\) Volume collected in t m³
\(dV/dt\) Filtration rate at V m³/s

Method and standards

Ruth equation.

Where it is used

  • Filter press and leaf filter cycles.
  • Sludge dewatering.

Common mistakes

  • Constants from a different pressure.
  • Compressible cakes.

Assumptions and limits

  • Constant pressure, incompressible cake.
  • With V = 0 and B = 0 the rate is unbounded and is not shown.

References

  • Ruth (1935) constant-pressure filtration t/V = (K_p/2)V + B (McCabe, Smith and Harriott)

Questions and answers

K_p 2 × 10⁶ s/m⁶, B 2 × 10⁴ s/m³, 0.2 m³?

733 minutes; in an hour 0.051 m³.

Why does the rate fall?

The cake grows and adds resistance.

Scale-up?

K_p scales with 1/area², B with 1/area.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.