Worked example
Example: Test constants, 0.2 m3 and 1 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Slope of t/V against V | 2,000,000 - |
| Intercept of t/V (s/m³) | 20,000 - |
| Filtrate volume | 0.20000 m³ |
| Filtration time | 60.000 min |
Applying the formula below gives:
| Result | Value |
|---|---|
| Time to collect V | 733.33 min |
| Volume collected in t | 0.050828 m³ |
| Filtration rate at V | 0.008571 m³/h |
Open this example in the calculator and change any input.
Formula
\(t = \frac{K_p}{2}V^2 + B V, \quad V = \frac{-B + \sqrt{B^2 + 2K_p t}}{K_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(K_p\) | Slope of t/V against V | - |
| \(B\) | Intercept of t/V (s/m³) | - |
| \(V\) | Filtrate volume | m³ |
| \(t\) | Filtration time | s |
| \(t(V)\) | Time to collect V | s |
| \(V(t)\) | Volume collected in t | m³ |
| \(dV/dt\) | Filtration rate at V | m³/s |
Method and standards
Ruth equation.
Where it is used
- Filter press and leaf filter cycles.
- Sludge dewatering.
Common mistakes
- Constants from a different pressure.
- Compressible cakes.
Assumptions and limits
- Constant pressure, incompressible cake.
- With V = 0 and B = 0 the rate is unbounded and is not shown.
References
- Ruth (1935) constant-pressure filtration t/V = (K_p/2)V + B (McCabe, Smith and Harriott)
Questions and answers
K_p 2 × 10⁶ s/m⁶, B 2 × 10⁴ s/m³, 0.2 m³?
733 minutes; in an hour 0.051 m³.
Why does the rate fall?
The cake grows and adds resistance.
Scale-up?
K_p scales with 1/area², B with 1/area.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.