FireCADCalc

Relative Volatility and K-Values from Antoine Constants

Vapour pressures, ideal K-values and relative volatility of two components at a temperature and pressure from their Antoine constants (mmHg, °C form).

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Benzene-toluene at 95 °CSame pair at 110 °C, 1.5 bar

Component 1 (Antoine constants in log10(p/mmHg) = A − B/(C + t/°C))

mmHg and °C form (not the bar and K form of the bubble and dew point page). Defaults: the commonly tabulated benzene and toluene sets; check the range in your source.

Component 2 (Antoine constants in log10(p/mmHg) = A − B/(C + t/°C))

Results

Antoine constants for log₁₀(p/mmHg) and t in °C, valid only over their stated range; ideal (Raoult) K-values.

Vapour pressure 1234.16kPa
Vapour pressure 299.537kPa
K-value 1 (ideal)1.5611
K-value 2 (ideal)0.66358
Relative volatility2.3525

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Benzene-toluene at 95 °C. The inputs, in the units selected above:

InputValue
Component 1 (light): A6.9056 -
Component 1: B1,211.0 -
Component 1: C220.79 -
Component 2 (heavy): A6.9546 -
Component 2: B1,344.8 -
Component 2: C219.48 -
Temperature95.000 °C
Pressure (absolute)101.33 kPa

Applying the formula below gives:

ResultValue
Vapour pressure 1156.90 kPa
Vapour pressure 263.578 kPa
K-value 1 (ideal)1.5485
K-value 2 (ideal)0.62746
Relative volatility2.4678

Open this example in the calculator and change any input.

Formula

\(\log_{10} p^{sat} = A - \frac{B}{C + t}, \quad K_i = \frac{p_i^{sat}}{p}, \quad \alpha_{12} = \frac{p_1^{sat}}{p_2^{sat}}\)

Variables

Symbol Meaning SI unit
\(A_1\) Component 1 (light): A -
\(B_1\) Component 1: B -
\(C_1\) Component 1: C -
\(A_2\) Component 2 (heavy): A -
\(B_2\) Component 2: B -
\(C_2\) Component 2: C -
\(T\) Temperature K
\(p\) Pressure (absolute) Pa
\(p_1^{sat}\) Vapour pressure 1 Pa
\(p_2^{sat}\) Vapour pressure 2 Pa
\(K_1\) K-value 1 (ideal) -
\(K_2\) K-value 2 (ideal) -
\(\alpha_{12}\) Relative volatility -

Method and standards

Antoine and Raoult.

Where it is used

  • Distillation shortcut design.
  • Flash K-values.

Common mistakes

  • Constants in a different unit form.
  • Outside the valid range.

Assumptions and limits

  • Ideal liquid and vapour.
  • Antoine constants in the mmHg and °C form, log₁₀(p/mmHg) = A − B/(C + t/°C); the bubble and dew point page uses the bar and K form instead.
  • The defaults are a commonly tabulated benzene and toluene set; each set holds only over its own temperature range, which the page does not check.

References

  • Antoine equation log₁₀p = A − B/(C + t); Raoult K = p_sat/p; α = p₁_sat/p₂_sat

Questions and answers

Benzene and toluene at 95 °C?

α about 2.47.

Where are Antoine constants?

Property handbooks; check the units and range.

Non-ideal mixtures?

Multiply by activity coefficients (see Margules).

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.