FireCADCalc

Onda Correlations: Wetted Area, kL, kG and HOG for Packed Columns

Effective wetted area, liquid and gas film coefficients by Onda's correlations, the film transfer unit heights and the overall HOG for a random-packed column.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: NH3 absorption, 50 mm metal Pall rings (102 m2/m3), steelStripping with 12 mm plastic rings (small packing K5 2.0)

Accepted: 0.01 to 100 kg/(m²·s)
Accepted: 0.01 to 20 kg/(m²·s)
Accepted: 0.01 to 1 m²/L
Accepted: 5 to 150 mm
Accepted: 10 to 100 mN/m
Accepted: 5 to 100 mN/m
Accepted: 0.01 to 100 mPa·s
Accepted: 300 to 2,000 kg/m³
Accepted: 1E-11 to 1E-7 m²/s
Accepted: 0.001 to 0.1 mPa·s
Accepted: 0.05 to 100 kg/m³
Accepted: 1E-7 to 0.001 m²/s
Accepted: -23.15 to 326.85 °C
Accepted: 0.1 to 100 bar
Accepted: 2 to 400 kg/kmol
Accepted: 2 to 400 kg/kmol
Accepted: 0 to 1,000

Results

Onda, Takeuchi and Okumoto (1968): K₅ = 5.23 for packings above 15 mm and 2.00 below. Onda's predictions are typically within ±30 %; Designers recommend comparing with Cornell's method and using the larger height.

Wetted fraction of packing area72.514%
Effective interfacial area73.964m²/m³
Liquid film coefficient0.21258mm/s
Gas film coefficient, kmol/(m²·s·bar)0.001697
Gas film transfer unit height0.40671m
Liquid film transfer unit height0.50982m
Stripping factor0.13966
Overall gas-phase transfer unit height0.47791m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: NH3 absorption, 50 mm metal Pall rings (102 m2/m3), steel. The inputs, in the units selected above:

InputValue
Liquid mass flux8.0000 kg/(m²·s)
Gas mass flux1.5000 kg/(m²·s)
Packing specific area0.10200 m²/L
Nominal packing size50.000 mm
Critical surface tension of the packing (ceramic 61, steel 75, polyethylene 33)75.000 mN/m
Liquid surface tension72.000 mN/m
Liquid viscosity1.0000 mPa·s
Liquid density998.00 kg/m³
Liquid diffusivity2.0000e-09 m²/s
Gas viscosity0.018000 mPa·s
Gas density1.2000 kg/m³
Gas diffusivity2.1000e-05 m²/s
Temperature25.000 °C
Pressure1.0130 bar
Liquid molar mass18.000 kg/kmol
Gas molar mass29.000 kg/kmol
Equilibrium line slope (y = mx)1.2000 -

Applying the formula below gives:

ResultValue
Wetted fraction of packing area72.514 %
Effective interfacial area73.964 m²/m³
Liquid film coefficient0.21258 mm/s
Gas film coefficient, kmol/(m²·s·bar)0.001697
Gas film transfer unit height0.40671 m
Liquid film transfer unit height0.50982 m
Stripping factor0.13966
Overall gas-phase transfer unit height0.47791 m

Open this example in the calculator and change any input.

Formula

\(\frac{a_w}{a} = 1 - \exp\left[-1.45\left(\frac{\sigma_c}{\sigma_L}\right)^{0.75}\left(\frac{L_w^*}{a\mu_L}\right)^{0.1}\left(\frac{L_w^{*2}a}{\rho_L^2g}\right)^{-0.05}\left(\frac{L_w^{*2}}{\rho_L\sigma_La}\right)^{0.2}\right]\)

\(k_L\left(\frac{\rho_L}{\mu_Lg}\right)^{1/3} = 0.0051\left(\frac{L_w^*}{a_w\mu_L}\right)^{2/3}\left(\frac{\mu_L}{\rho_LD_L}\right)^{-1/2}(ad_p)^{0.4}, \quad \frac{k_GRT}{aD_v} = K_5\left(\frac{V_w^*}{a\mu_v}\right)^{0.7}\left(\frac{\mu_v}{\rho_vD_v}\right)^{1/3}(ad_p)^{-2.0}\)

\(H_G = \frac{G_m}{k_Ga_wP}, \quad H_L = \frac{L_m}{k_La_wC_t}, \quad H_{OG} = H_G + m\frac{G_m}{L_m}H_L\)

Variables

Symbol Meaning SI unit
\(L_w^*\) Liquid mass flux kg/(m²·s)
\(V_w^*\) Gas mass flux kg/(m²·s)
\(a\) Packing specific area m²/m³
\(d_p\) Nominal packing size m
\(\sigma_c\) Critical surface tension of the packing (ceramic 61, steel 75, polyethylene 33) N/m
\(\sigma_L\) Liquid surface tension N/m
\(\mu_L\) Liquid viscosity Pa·s
\(\rho_L\) Liquid density kg/m³
\(D_L\) Liquid diffusivity m²/s
\(\mu_v\) Gas viscosity Pa·s
\(\rho_v\) Gas density kg/m³
\(D_v\) Gas diffusivity m²/s
\(T\) Temperature K
\(P\) Pressure Pa
\(M_L\) Liquid molar mass kg/kmol
\(M_V\) Gas molar mass kg/kmol
\(m\) Equilibrium line slope (y = mx) -
\(a_w/a\) Wetted fraction of packing area -
\(a_w\) Effective interfacial area m²/m³
\(k_L\) Liquid film coefficient m/s
\(k_G\) Gas film coefficient, kmol/(m²·s·bar) -
\(H_G\) Gas film transfer unit height m
\(H_L\) Liquid film transfer unit height m
\(mG_m/L_m\) Stripping factor -
\(H_{OG}\) Overall gas-phase transfer unit height m

Method and standards

Onda's film coefficient and wetted-area correlations.

Where it is used

  • Packed absorber and stripper design.
  • Comparing packing materials and sizes.

Common mistakes

  • Using the total packing area instead of the wetted area.
  • Mixing K₅ values for small and large packings.

Assumptions and limits

  • Random packings; Onda's data range.

Questions and answers

Why does the packing material matter?

Through its critical surface tension: water wets ceramics (61 mN/m) and metals better than plastics (33 mN/m), so more of a plastic packing's area stays dry.

How is H_OG used?

Packed height Z = H_OG × N_OG; N_OG comes from the Colburn equation or a numerical integration.

What do the defaults represent?

An illustrative case: NH3 absorption, 50 mm metal Pall rings (102 m2/m3), steel. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Sinnott, Coulson and Richardson's Chemical Engineering Vol. 6: Chemical Engineering Design, 4th ed. (Elsevier, 2005), sec. 11.14.4, eqs. 11.113 to 11.117 and Example 11.14 (Onda, Takeuchi and Okumoto, 1968)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.