FireCADCalc

NRTL Activity Coefficients for a Binary Mixture

Activity coefficients of a binary liquid by the NRTL equation from user parameters b₁₂, b₂₁ and non-randomness α, with infinite-dilution values.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: x = 0.3, 80 °C, 2000/4000 cal/molNegative b12

An energy (J/mol or cal/mol). Parameters tabulated in kelvin (b/R) must be multiplied by R = 8.314 J/(mol·K) or 1.987 cal/(mol·K).
An energy (J/mol or cal/mol). Parameters tabulated in kelvin (b/R) must be multiplied by R = 8.314 J/(mol·K) or 1.987 cal/(mol·K).

Results

Activity coefficient of 13.9322
Activity coefficient of 21.7817
γ₁ at infinite dilution1,004.1
γ₂ at infinite dilution48.466

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: x = 0.3, 80 °C, 2000/4000 cal/mol. The inputs, in the units selected above:

InputValue
Mole fraction of component 130.000 %
Temperature80.000 °C
NRTL parameter b₁₂2,000.0 cal/mol
NRTL parameter b₂₁4,000.0 cal/mol
Non-randomness α0.30000 -

Applying the formula below gives:

ResultValue
Activity coefficient of 13.9322
Activity coefficient of 21.7817
γ₁ at infinite dilution1,004.1
γ₂ at infinite dilution48.466

Open this example in the calculator and change any input.

Formula

\(\ln\gamma_1 = x_2^2\left[\tau_{21}\left(\frac{G_{21}}{x_1 + x_2G_{21}}\right)^2 + \frac{\tau_{12}G_{12}}{(x_2 + x_1G_{12})^2}\right], \quad \tau_{ij} = \frac{b_{ij}}{RT}, \quad G_{ij} = e^{-\alpha\tau_{ij}}\)

Variables

Symbol Meaning SI unit
\(x_1\) Mole fraction of component 1 -
\(T\) Temperature K
\(b_{12}\) NRTL parameter b₁₂ J/mol
\(b_{21}\) NRTL parameter b₂₁ J/mol
\(\alpha\) Non-randomness α -
\(\gamma_1\) Activity coefficient of 1 -
\(\gamma_2\) Activity coefficient of 2 -
\(\gamma_1^\infty\) γ₁ at infinite dilution -
\(\gamma_2^\infty\) γ₂ at infinite dilution -
\(\tau_{12}, \tau_{21}, G_{12}, G_{21}\) NRTL interaction terms -
\(R\) Gas constant 8.314 462 618 J/(mol·K)

Method and standards

NRTL equation as given in Perry's sec. 4.

Where it is used

  • Liquid–liquid and vapour–liquid equilibrium.
  • Checking simulator parameters.

Common mistakes

  • Swapping parameter order.
  • Using a different τ convention.

Assumptions and limits

  • Binary; parameters valid near their fitted temperatures.
  • b₁₂ and b₂₁ are energies (J/mol or cal/mol). Data banks that list them in kelvin (b/R) need them multiplied by R first.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 4 (thermodynamics: excess Gibbs energy models)
  • NRTL equation (Renon and Prausnitz)

Questions and answers

What is α?

The non-randomness parameter, usually 0.2–0.47; 0.3 is common for miscible systems.

Which convention is used?

τ₁₂ = b₁₂/RT, G₁₂ = exp(−ατ₁₂), as in Perry's; check that literature parameters use the same.

Why do published sets disagree?

Different conventions and fits; always check against data before use.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.