Worked example
Example: x = 0.3, 80 °C, 2000/4000 cal/mol. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mole fraction of component 1 | 30.000 % |
| Temperature | 80.000 °C |
| NRTL parameter b₁₂ | 2,000.0 cal/mol |
| NRTL parameter b₂₁ | 4,000.0 cal/mol |
| Non-randomness α | 0.30000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Activity coefficient of 1 | 3.9322 |
| Activity coefficient of 2 | 1.7817 |
| γ₁ at infinite dilution | 1,004.1 |
| γ₂ at infinite dilution | 48.466 |
Open this example in the calculator and change any input.
Formula
\(\ln\gamma_1 = x_2^2\left[\tau_{21}\left(\frac{G_{21}}{x_1 + x_2G_{21}}\right)^2 + \frac{\tau_{12}G_{12}}{(x_2 + x_1G_{12})^2}\right], \quad \tau_{ij} = \frac{b_{ij}}{RT}, \quad G_{ij} = e^{-\alpha\tau_{ij}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_1\) | Mole fraction of component 1 | - |
| \(T\) | Temperature | K |
| \(b_{12}\) | NRTL parameter b₁₂ | J/mol |
| \(b_{21}\) | NRTL parameter b₂₁ | J/mol |
| \(\alpha\) | Non-randomness α | - |
| \(\gamma_1\) | Activity coefficient of 1 | - |
| \(\gamma_2\) | Activity coefficient of 2 | - |
| \(\gamma_1^\infty\) | γ₁ at infinite dilution | - |
| \(\gamma_2^\infty\) | γ₂ at infinite dilution | - |
| \(\tau_{12}, \tau_{21}, G_{12}, G_{21}\) | NRTL interaction terms | - |
| \(R\) | Gas constant 8.314 462 618 | J/(mol·K) |
Method and standards
NRTL equation as given in Perry's sec. 4.
Where it is used
- Liquid–liquid and vapour–liquid equilibrium.
- Checking simulator parameters.
Common mistakes
- Swapping parameter order.
- Using a different τ convention.
Assumptions and limits
- Binary; parameters valid near their fitted temperatures.
- b₁₂ and b₂₁ are energies (J/mol or cal/mol). Data banks that list them in kelvin (b/R) need them multiplied by R first.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 4 (thermodynamics: excess Gibbs energy models)
- NRTL equation (Renon and Prausnitz)
Questions and answers
What is α?
The non-randomness parameter, usually 0.2–0.47; 0.3 is common for miscible systems.
Which convention is used?
τ₁₂ = b₁₂/RT, G₁₂ = exp(−ατ₁₂), as in Perry's; check that literature parameters use the same.
Why do published sets disagree?
Different conventions and fits; always check against data before use.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.