FireCADCalc

Murphree Tray Efficiency to Overall Column Efficiency

Overall column efficiency from the Murphree vapour efficiency and the stripping factor λ = mV/L (Lewis's relation, straight equilibrium and operating lines).

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: E_MV 0.7, λ 1.2Absorber λ 0.6

Results

Lewis's relation assumes vapour and liquid fully mixed between trays and straight lines over the section; apply it per section.

Stripping factor mV/L1.2000
Overall efficiency71.867%
Actual trays21.000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: E_MV 0.7, λ 1.2. The inputs, in the units selected above:

InputValue
Murphree vapour efficiency70.000 %
Equilibrium line slope1.2000 -
Vapour-to-liquid molar ratio1.0000 -
Theoretical stages15.000 -

Applying the formula below gives:

ResultValue
Stripping factor mV/L1.2000
Overall efficiency71.867 %
Actual trays21.000

Open this example in the calculator and change any input.

Formula

\(E_o = \frac{\ln[1 + E_{MV}(\lambda - 1)]}{\ln\lambda}, \quad \lambda = \frac{mV}{L}\)

Variables

Symbol Meaning SI unit
\(E_{MV}\) Murphree vapour efficiency -
\(m\) Equilibrium line slope -
\(V/L\) Vapour-to-liquid molar ratio -
\(N_t\) Theoretical stages -
\(\lambda\) Stripping factor mV/L -
\(E_o\) Overall efficiency -
\(N_a\) Actual trays -

Method and standards

Lewis relation.

Where it is used

  • Converting tray test data to column design.
  • Absorber and stripper design.

Common mistakes

  • Applying one λ to the whole column.
  • Mixing liquid and vapour Murphree efficiencies.

Assumptions and limits

  • Straight lines; mixed vapour and liquid.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 14 (E_o = ln[1 + E_MV(λ − 1)]/ln λ)

Questions and answers

When are Murphree and overall efficiency equal?

When λ = 1, that is, equilibrium and operating lines are parallel.

Why is overall efficiency lower when λ < 1?

In absorbers with λ below 1, each tray's shortfall compounds differently; E_o falls below E_MV.

What do the defaults represent?

A section with E_MV 70 % and λ = 1.2.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.