Worked example
Example: E_MV 0.7, λ 1.2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Murphree vapour efficiency | 70.000 % |
| Equilibrium line slope | 1.2000 - |
| Vapour-to-liquid molar ratio | 1.0000 - |
| Theoretical stages | 15.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stripping factor mV/L | 1.2000 |
| Overall efficiency | 71.867 % |
| Actual trays | 21.000 |
Open this example in the calculator and change any input.
Formula
\(E_o = \frac{\ln[1 + E_{MV}(\lambda - 1)]}{\ln\lambda}, \quad \lambda = \frac{mV}{L}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E_{MV}\) | Murphree vapour efficiency | - |
| \(m\) | Equilibrium line slope | - |
| \(V/L\) | Vapour-to-liquid molar ratio | - |
| \(N_t\) | Theoretical stages | - |
| \(\lambda\) | Stripping factor mV/L | - |
| \(E_o\) | Overall efficiency | - |
| \(N_a\) | Actual trays | - |
Method and standards
Lewis relation.
Where it is used
- Converting tray test data to column design.
- Absorber and stripper design.
Common mistakes
- Applying one λ to the whole column.
- Mixing liquid and vapour Murphree efficiencies.
Assumptions and limits
- Straight lines; mixed vapour and liquid.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 14 (E_o = ln[1 + E_MV(λ − 1)]/ln λ)
Questions and answers
When are Murphree and overall efficiency equal?
When λ = 1, that is, equilibrium and operating lines are parallel.
Why is overall efficiency lower when λ < 1?
In absorbers with λ below 1, each tray's shortfall compounds differently; E_o falls below E_MV.
What do the defaults represent?
A section with E_MV 70 % and λ = 1.2.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.