Worked example
Example: Light non-key α 3, Nmin 8. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Minimum stages | 8.0000 - |
| Volatility of the component relative to the heavy key | 3.0000 - |
| Heavy-key split distillate/bottoms | 0.050000 - |
| Component in the feed | 10.000 kmol/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Component split distillate/bottoms | 328.05 |
| In the distillate | 9.9696 kmol/h |
| In the bottoms | 0.030391 kmol/h |
| Recovered in the distillate | 99.696 % |
Open this example in the calculator and change any input.
Formula
\(\left(\frac{d}{b}\right)_i = \alpha_i^{N_{min}}\left(\frac{d}{b}\right)_{HK}, \quad d_i = f_i\frac{(d/b)_i}{1 + (d/b)_i}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N_{min}\) | Minimum stages | - |
| \(\alpha_i\) | Volatility of the component relative to the heavy key | - |
| \((d/b)_{HK}\) | Heavy-key split distillate/bottoms | - |
| \(f_i\) | Component in the feed | mol/s |
| \((d/b)_i\) | Component split distillate/bottoms | - |
| \(d_i\) | In the distillate | mol/s |
| \(b_i\) | In the bottoms | mol/s |
| \(d_i/f_i\) | Recovered in the distillate | - |
Method and standards
Perry's Eq. (13-31) with the heavy key as reference.
Where it is used
- Multicomponent short-cut design.
Common mistakes
- Using α relative to the light key with the heavy-key split.
Assumptions and limits
- Constant α; total reflux distribution.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 13 (distillation)
- Eq. (13-31)
Questions and answers
Why at total reflux?
Fenske's equation is exact only at total reflux; at finite reflux it is a good first estimate.
What α to use?
The geometric mean of top and bottom values relative to the heavy key.
How do non-keys distribute?
Lighter than the light key: almost all overhead; heavier than the heavy key: almost all in the bottoms.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.