FireCADCalc

Dryer Moisture Balance: Wet and Dry Basis

Water to evaporate in a dryer from the wet feed rate and the inlet and outlet moisture on a wet basis, with dry-basis moistures and the product rate.

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 35 % to 8 %Bagasse 50 % to 35 %

Results

Dry solids10,000kg/h
Dried product15,385kg/h
Water evaporated4,615.4kg/h
Inlet moisture (dry basis)1.0000
Outlet moisture (dry basis)0.53846

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 35 % to 8 %. The inputs, in the units selected above:

InputValue
Wet feed rate2,000.0 kg/h
Inlet moisture (wet basis)35.000 %
Outlet moisture (wet basis)8.0000 %

Applying the formula below gives:

ResultValue
Dry solids1,300.0 kg/h
Dried product1,413.0 kg/h
Water evaporated586.96 kg/h
Inlet moisture (dry basis)0.53846
Outlet moisture (dry basis)0.086957

Open this example in the calculator and change any input.

Formula

\(\dot m_s = \dot m_F(1 - M_1), \quad \dot m_P = \frac{\dot m_s}{1 - M_2}, \quad \dot m_w = \dot m_F - \dot m_P, \quad X = \frac{M}{1 - M}\)

Variables

Symbol Meaning SI unit
\(\dot m_F\) Wet feed rate kg/s
\(M_1\) Inlet moisture (wet basis) -
\(M_2\) Outlet moisture (wet basis) -
\(\dot m_s\) Dry solids kg/s
\(\dot m_P\) Dried product kg/s
\(\dot m_w\) Water evaporated kg/s
\(X_1\) Inlet moisture (dry basis) -
\(X_2\) Outlet moisture (dry basis) -

Method and standards

Dry-solids balance.

Where it is used

  • Dryer sizing for bagasse, coal, sludge and chemicals.
  • Heat duty estimates.

Common mistakes

  • Subtracting percentages.
  • Mixing wet and dry bases.

Assumptions and limits

  • No solids loss.

References

  • Dry-solids balance; X = M/(1 − M)

Questions and answers

2000 kg/h at 35 % dried to 8 %?

587 kg/h of water to evaporate.

Why not 35 − 8 = 27 %?

The percentages are of different total masses.

Dry basis?

Water per kg of dry solid: 0.54 in and 0.087 out here.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.