FireCADCalc

Clausius–Clapeyron: Vapour Pressure at Another Temperature

Vapour pressure at a second temperature from one known point and the heat of vaporisation, and the boiling point at a chosen pressure (Clausius–Clapeyron).

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: EthanolWater from 100 °C

Results

Constant heat of vaporisation; best over modest temperature ranges.

Vapour pressure at T₂48.290kPa
Boiling point at p_t58.860°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ethanol. The inputs, in the units selected above:

InputValue
Known vapour pressure101.33 kPa
Temperature of the known point78.250 °C
Heat of vaporisation (molar)38.560 kJ/mol
Temperature wanted50.000 °C
Pressure for the boiling point50.000 kPa

Applying the formula below gives:

ResultValue
Vapour pressure at T₂31.963 kPa
Boiling point at p_t60.399 °C

Open this example in the calculator and change any input.

Formula

\(\ln\frac{p_2}{p_1} = -\frac{\Delta H_v}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right)\)

Variables

Symbol Meaning SI unit
\(p_1\) Known vapour pressure Pa
\(T_1\) Temperature of the known point K
\(\Delta H_v\) Heat of vaporisation (molar) J/mol
\(T_2\) Temperature wanted K
\(p_t\) Pressure for the boiling point Pa
\(p_2\) Vapour pressure at T₂ Pa
\(T_b\) Boiling point at p_t K

Method and standards

Clausius–Clapeyron.

Where it is used

  • Vacuum distillation and evaporation.
  • Solvent recovery.

Common mistakes

  • Specific instead of molar ΔH.
  • Long extrapolation.

Assumptions and limits

  • Constant ΔH_v, ideal vapour.

References

  • Clausius–Clapeyron ln(p₂/p₁) = −(ΔH_v/R)(1/T₂ − 1/T₁)

Questions and answers

Ethanol, boiling at 78.3 °C, at 50 °C?

About 32.0 kPa (measured about 29.5 kPa).

Boiling point at 50 kPa?

About 60 °C.

Better accuracy?

Use Antoine constants over the range you need.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.