Vapour Pressure and Boiling Point by the Antoine Equation

Vapour pressure of a liquid at a temperature, and its boiling point at a pressure, from Antoine constants in bar and K, mmHg and °C, or kPa and °C.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Water at 50 °C; boiling point at 1 atm (bar, K constants)Same water set in mmHg and °C: 80 °C, boiling at 50 kPaSame water set in kPa and °C: 20 °C, boiling at 20 kPa

Defaults: water, 255.9–373 K, NIST Chemistry WebBook (Stull, 1947).

Results

Antoine constants hold only over the temperature range they were fitted to; outside it the result can be far off.

Vapour pressure at T0.12525bar
Boiling point at p100.45°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water at 50 °C; boiling point at 1 atm (bar, K constants). The inputs, in the units selected above:

InputValue
Units of the constantsp in bar, T in K (NIST WebBook form)
Antoine constant A4.6543 -
Antoine constant B1,435.3 -
Antoine constant C-64.848 -
Temperature50.000 °C
Pressure for the boiling point1.0132 bar

Applying the formula below gives:

ResultValue
Vapour pressure at T0.12525 bar
Boiling point at p100.45 °C

Open this example in the calculator and change any input.

Formula

\(\log_{10} p_v = A - \frac{B}{T + C}\)

\(T_b = \frac{B}{A - \log_{10} p} - C\)

Variables

Symbol Meaning SI unit
\(\text{units}\) Units of the constants -
\(A\) Antoine constant A -
\(B\) Antoine constant B -
\(C\) Antoine constant C -
\(T\) Temperature K
\(p\) Pressure for the boiling point Pa
\(p_v\) Vapour pressure at T Pa
\(T_b\) Boiling point at p K

Method and standards

Antoine's three-constant fit of vapour pressure against temperature; the constants carry units, so the unit option sets how T and p enter.

Where it is used

  • Solvent recovery and distillation estimates.
  • Tank breathing and vent loss checks.
  • Vacuum boiling temperatures.

Common mistakes

  • Mixing the unit convention of the constants.
  • Using constants outside their fitted range.
  • Using natural instead of base-10 logarithms.

Assumptions and limits

  • Within the constants' temperature range. Even at the end of the range the inverted boiling point can be off: the water set gives 100.45 °C at 1 atm against 99.97 °C from IAPWS-IF97.
  • A boiling point at or below absolute zero is not shown.

References

  • C. Antoine (1888); NIST Chemistry WebBook Antoine parameters

Questions and answers

What vapour pressure does water have at 50 °C?

With the NIST set (Stull, 1947) 12.5 kPa; IAPWS-IF97 gives 12.35 kPa, so this set is within about 1.5 %.

How do I find the boiling point?

Invert the equation: T = B/(A − log p) − C. The water set gives 100.5 °C at 1 atm.

Which units do my constants use?

Check the source: NIST uses bar and K; many handbooks use mmHg and °C. Choose the matching option.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.