Worked example
Example: Water at 50 °C; boiling point at 1 atm (bar, K constants). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Units of the constants | p in bar, T in K (NIST WebBook form) |
| Antoine constant A | 4.6543 - |
| Antoine constant B | 1,435.3 - |
| Antoine constant C | -64.848 - |
| Temperature | 50.000 °C |
| Pressure for the boiling point | 1.0132 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour pressure at T | 0.12525 bar |
| Boiling point at p | 100.45 °C |
Open this example in the calculator and change any input.
Formula
\(\log_{10} p_v = A - \frac{B}{T + C}\)
\(T_b = \frac{B}{A - \log_{10} p} - C\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{units}\) | Units of the constants | - |
| \(A\) | Antoine constant A | - |
| \(B\) | Antoine constant B | - |
| \(C\) | Antoine constant C | - |
| \(T\) | Temperature | K |
| \(p\) | Pressure for the boiling point | Pa |
| \(p_v\) | Vapour pressure at T | Pa |
| \(T_b\) | Boiling point at p | K |
Method and standards
Antoine's three-constant fit of vapour pressure against temperature; the constants carry units, so the unit option sets how T and p enter.
Where it is used
- Solvent recovery and distillation estimates.
- Tank breathing and vent loss checks.
- Vacuum boiling temperatures.
Common mistakes
- Mixing the unit convention of the constants.
- Using constants outside their fitted range.
- Using natural instead of base-10 logarithms.
Assumptions and limits
- Within the constants' temperature range. Even at the end of the range the inverted boiling point can be off: the water set gives 100.45 °C at 1 atm against 99.97 °C from IAPWS-IF97.
- A boiling point at or below absolute zero is not shown.
References
- C. Antoine (1888); NIST Chemistry WebBook Antoine parameters
Questions and answers
What vapour pressure does water have at 50 °C?
With the NIST set (Stull, 1947) 12.5 kPa; IAPWS-IF97 gives 12.35 kPa, so this set is within about 1.5 %.
How do I find the boiling point?
Invert the equation: T = B/(A − log p) − C. The water set gives 100.5 °C at 1 atm.
Which units do my constants use?
Check the source: NIST uses bar and K; many handbooks use mmHg and °C. Choose the matching option.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.